Skip to main content
Siemens 3RT2326-1AV00 — Contactors

Siemens 3RT2326-1AV00 SIRIUS Contactor, Size S0, 60 mm wide

MPN3RT2326-1AV00
Active

Siemens SIRIUS contactor, Size S0, order code 3RT2326-1AV00, 60 mm wide, 97 mm deep, screw and snap-on mounting for 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2326-1AV00 — Identification
ParameterValue
Contactor frame sizeS0
3RT2326-1AV00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V7.5 kW
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2326-1AV00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz400 V
3RT2326-1AV00 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2326-1AV00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2326-1AV00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2326-1AV00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2326-1AV00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2326-1AV00 — Mechanical
ParameterValue
Width60 mm
Height85 mm
Depth97 mm
3RT2326-1AV00 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, and the mounting position allows ±180° rotation on a vertical surface plus ±22.5° tilt forward or backward, giving panel builders flexibility in tight enclosures.

Size S0 is the mechanical frame that governs terminal capacity and thermal dissipation — it accepts stranded conductors up to 10 mm² and solid conductors from 0.5 to 2.5 mm² on the main circuit, with auxiliary contacts wired through 0.5 to 1.5 mm² solid or stranded. The auxiliary switch is rated for AC coil voltage and carries a range of contact ratings depending on the switched voltage: 10 A at 24 V and 230 V, 6 A at 60 V, 3 A at 400 V, down to 0.1 A at 600 V. These are the make/break capacities for the auxiliary circuit — not the main motor current — and they determine whether this contactor can drive the PLC input or relay load you need to switch.

The coil connection uses screw-type terminals. Arcing time is 10 to 10 ms at AC, with a switching frequency of 0.25 at 50 Hz. These numbers matter when laying out the gland plate and ensuring adequate fill factor — the 60 mm width and 97 mm depth are the dimensions that determine rail spacing in the enclosure.

Frequently asked questions

How do I get current pricing and availability for 3RT2326-1AV00?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; the part is sourced and quoted to order against an RFQ through independent distribution.

What is 3RT2326-1AV00's listed depth?

The depth is 97 mm, with a width of 60 mm and height of 85 mm.

Will 3RT2326-1AV00 drop into a panel specified around 3RT2326-1BK80 without rewiring?

Both are Size S0 SIRIUS contactors sharing the same 60 mm width and DIN rail mounting footprint, so the mechanical fit is identical. Terminal capacity and auxiliary contact configuration should be verified against your specific wiring — the 1AV00 carries screw-type coil terminals and a single instantaneous auxiliary contact.

MPN
3RT2326-1AV00