Skip to main content
Siemens 3RT2326-1BF40 — Contactors

Siemens 3RT2326-1BF40 SIRIUS Contactor, 110 VDC Coil, S0 Fra

MPN3RT2326-1BF40
Active

Siemens SIRIUS 3RT2326-1BF40, S0 frame contactor, 110 VDC coil, screw-type terminals, 1 NC + 1 NO auxiliary, 10 A at 24 VDC, 10 million mechanical cycles.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2326-1BF40 — Identification
ParameterValue
Contactor frame sizeS0
3RT2326-1BF40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V7.5 kW
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2326-1BF40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2326-1BF40 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2326-1BF40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 20 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2326-1BF40 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2326-1BF40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2326-1BF40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2326-1BF40 — Mechanical
ParameterValue
Width60 mm
Height85 mm
Depth107 mm

Product details

SIRIUS S0 Contactor with 110 VDC Coil

The Siemens 3RT2326-1BF40 is a SIRIUS S0-frame contactor with a 110 VDC magnet coil terminated at screw-type terminals. It carries an integrated auxiliary switch block (1 NC + 1 NO) and accepts up to two additional attachable auxiliary contact blocks for expanded signaling or interlocking. Rated for main contact duty at 16 A through 8 A depending on utilization category, this contactor is sized for motor loads up to 7.5 kW at 400 V AC-3. The DC coil pulls in reliably at 0.8 × rated voltage (88 VDC minimum pick-up) and holds through the full 1.1 × rated voltage over-range. The S0 footprint (85 mm high × 60 mm wide × 107 mm deep) fits standard panel layouts; clearance requirements are 10 mm upward, 10 mm forward, 10 mm downward, and 6 mm to the side.

Auxiliary Contact Ratings Across Voltages

The built-in auxiliary contacts are rated for a wide range of control voltages: 10 A at 24 VDC, 6 A at 60 VDC, 1 A at 110 VDC, 0.9 A at 125 VDC, 0.3 A at 220 VDC, and 0.1 A at 600 VDC. On the AC side, they handle 10 A at 230 VAC and 3 A at 400 VAC. This covers most PLC output and relay interface loads without derating.

Environmental and Wiring Details

Auxiliary and coil terminals accept solid wire 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²). The DC coil dropout time is 15 to 18 ms; arcing time is 10 ms.

Frequently asked questions

Where can I buy 3RT2326-1BF40 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 3RT2326-1BF40's listed depth?

The depth is 107 mm, with a width of 60 mm and height of 85 mm (S0 frame).

What wire sizes does the 3RT2326-1BF40 accept?

Main circuit terminals accept stranded wire 1 to 10 mm². Auxiliary and coil terminals accept solid wire 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²).

Will 3RT2326-1BF40 drop into a panel specified around 3RT2326-1BK80?

Both share the same S0 frame size and DIN-rail mounting pattern, so the physical footprint and clearance requirements are identical. The difference is the coil voltage — 3RT2326-1BF40 uses 110 VDC, while 3RT2326-1BK80 uses a different coil rating. Check the coil voltage matches your control circuit before swapping.

MPN
3RT2326-1BF40