Skip to main content
Siemens 3RT2346-1AK60 — Contactors

Siemens 3RT2346-1AK60 Contactor, AC-1 140 A, 4-Pole, 110 VAC

MPN3RT2346-1AK60
Active

Siemens SIRIUS 3RT2346-1AK60, AC-1 contactor, 140 A, 400 V / 40 °C, 4-pole, 110 V AC 50 Hz / 120 V 60 Hz coil, screw terminal, size S3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2346-1AK60 — Specifications
ParameterValue
Group codeR711
Product group5370
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 01-09-17

Product details

The Siemens 3RT2346-1AK60 is a 4-pole power contactor from the SIRIUS series, sized S3. The screw terminals on the S3 frame accept standard lug or ring terminations, and the built-in auxiliary contact block (1 NO + 1 NC) gives you one feedback signal for the PLC and one for a status lamp or interlock without adding a side-mount module.

RoHS compliance is confirmed since 01-09-17, and REACH Article 33 candidate-list information is available on request.

The S3 frame footprint (146 x 136 x 177 mm packaged) mounts on standard DIN rail or panel plate. The 4-pole configuration means it occupies the width of a standard S3 contactor — about 55 mm on the rail — leaving room alongside for overload relays or busbar systems. The 110 V AC coil draws inrush current at pickup; verify your control transformer is sized for the magnetizing surge if multiple contactors pull in simultaneously.

What the AC-1 rating means for selection

AC-1 is the resistive load category — heaters, incandescent lighting, resistive banks. If your load is motor (AC-3) or mixed, you need the motor-rated version (3RT2... with a different coil code) because the AC-3 breaking current is lower for the same frame. This part is for resistive switching, not motor starting.

Frequently asked questions

What compliance documentation is available for this contactor?

RoHS compliance is confirmed since 01-09-17. REACH Article 33 candidate-list information is available. Export control is AL N / ECCN EAR99.

What coil voltage does this contactor use?

The coil is rated 110 V AC at 50 Hz and 120 V AC at 60 Hz. It accepts both frequencies without a jumper change.

MPN
3RT2346-1AK60