Siemens 3RT2346-1AN60 SIRIUS Contactor, S3 Frame, 96 mm Wide

MPN3RT2346-1AN60
Active

Siemens SIRIUS 3RT2346-1AN60 contactor, S3 frame size, 96 mm width, screw and snap-on 35 mm DIN rail mounting, auxiliary switch included, AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2346-1AN60 — Identification
ParameterValue
Contactor frame sizeS3
3RT2346-1AN60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2346-1AN60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.35
Rated value @ 50 Hz200 V
3RT2346-1AN60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2346-1AN60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegR: 250 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2346-1AN60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2346-1AN60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2346-1AN60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2346-1AN60 — Mechanical
ParameterValue
Width96 mm
Height140 mm
Depth152 mm
3RT2346-1AN60 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

S3 frame, 96 mm wide — what the DIN rail space buys you

The 3RT2346-1AN60 is a SIRIUS contactor in the S3 frame size, 96 mm wide, 140 mm tall, 152 mm deep. That width is the first thing to check against your DIN rail layout — it's wider than the S2 frame (which is 55 mm) and narrower than the S6 (which is 120 mm). If your panel was laid out for a different frame, the mounting holes and rail clip won't line up without a bracket. These are the minimum air gaps to adjacent metal or enclosures — ignore them and you'll get tracking or arc flash between phases on a fault.

Wire terminations — main and auxiliary

Main contacts accept stranded wire from 6 to 70 mm². That's a wide range — a 6 mm² tail for control transformers or a 70 mm² feed for a 50 hp motor both fit without adapters. The magnet coil uses screw-type terminals. Coil voltage is AC only — no DC coil option on this variant. If your control voltage is 24 VDC, you need the DC coil version (3RT2346-1AN60 is AC).

Auxiliary contacts and switching capacity

This contactor includes an auxiliary switch block — 2 contacts, configurable as NO or NC depending on wiring. The main contacts are 3-pole (10... 2 configuration, meaning 3 main poles). These are the make/break capacities — don't exceed them or the contacts weld shut.

Mechanical endurance is 10 million operations typical. Arcing time is 10 to 20 ms; operating time on AC is 10 to 21 ms. Shock resistance: 10.6 g for 5 ms and 6.3 g for 10 ms on DC — relevant if this contactor is mounted on a vibrating conveyor or press.

The lifecycle stage is listed as current — meaning Siemens still produces this part number. For BOM freeze or long-term planning, this is an active line item.

Frequently asked questions

What is the width of 3RT2346-1AN60?

The width is 96 mm. Depth is 152 mm, height is 140 mm. This is the S3 frame size.

What wire sizes does the main contact accept?

Stranded wire from 6 mm² to 70 mm².

Does this contactor include auxiliary contacts?

Yes, it includes an auxiliary switch block with 2 contacts. The main contacts are 3-pole.

MPN
3RT2346-1AN60