Siemens 3RT2346-1AP00-4AA0 — Contactors

Siemens 3RT2346-1AP00-4AA0 SIRIUS Contactor, Size S3, 70 mm

MPN3RT2346-1AP00-4AA0
Active

Siemens SIRIUS 3RT2346-1AP00-4AA0 contactor, Size S3, 70 mm width, 152 mm depth, 140 mm height, screw and snap-on DIN rail mounting, AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2346-1AP00-4AA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT2346-1AP00-4AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V45 kW
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2346-1AP00-4AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.38
Rated value @ 50 Hz230 V
3RT2346-1AP00-4AA0 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2346-1AP00-4AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2346-1AP00-4AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2346-1AP00-4AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2346-1AP00-4AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2346-1AP00-4AA0 — Mechanical
ParameterValue
Width70 mm
Height140 mm
Depth152 mm
3RT2346-1AP00-4AA0 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

Size S3 frame, 70 mm wide — panel fit

The 3RT2346-1AP00-4AA0: This is a Size S3 frame contactor from the SIRIUS line, measuring 70 mm wide by 152 mm deep by 140 mm tall.

Auxiliary contact ratings across the voltage range

At 690 V AC the rating is just 1 A. For DC switching, the 24 V rated value is 10 A, 48 V is 2 A, 60 V is 6 A, 110 V is 1 A, 125 V is 0.9 A, 220 V is 0.3 A, 500 V is 2 A, and 690 V is 1 A. These are the make/break limits for resistive loads — inductive loads will need derating per the application note.

Coil data and operating conditions

The magnet coil uses screw-type terminals and is rated for AC supply. At 50 Hz the coil power draw is 0.38 (likely VA or W — the unit is implied by the field). The arcing time across the main contacts is 10 to 21 ms at AC, with a total arcing time of 10 to 20 ms. The mechanical endurance is 10 million operating cycles typical.

Wiring and short-circuit protection

Main circuit wiring accepts stranded conductors from 6 to 70 mm². For short-circuit protection, the required fuse is type gB rated 200 A at 750 V with a 25 kA breaking capacity. This sets the SCCR for the contactor branch in the panel.

MPN
3RT2346-1AP00-4AA0