MPN3RT2346-1NP30-4AA0
Active

Siemens SIRIUS S3 contactor, 3RT2346-1NP30-4AA0, 175-280 V AC/DC coil, screw-type terminals, screw and snap-on 35 mm DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT2346-1NP30-4AA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT2346-1NP30-4AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V45 kW
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2346-1NP30-4AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz3.5 VA
Rated value @ 50 Hz175 ... 280 V
3RT2346-1NP30-4AA0 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2346-1NP30-4AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A (415 V, 80 kA)
Short-circuit coordination type 2, fusegG: 160 A (690 V, 100 kA), aM: 100 A (690 V, 100 kA), BS88: 125 A (415 V, 80 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2346-1NP30-4AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2346-1NP30-4AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2346-1NP30-4AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2346-1NP30-4AA0 — Mechanical
ParameterValue
Width96 mm
Height140 mm
Depth152 mm
3RT2346-1NP30-4AA0 — Specifications
ParameterValue
At AC38 ... 57 ms

Product details

Part identity and deployment

Coil and switching behaviour

Coil pickup and dropout times are identical for AC and DC: 38-57 ms for closing, with an arcing time of 10-20 ms. Holding power at 50/60 Hz is 3.5 VA.

Main power terminals accept stranded conductors from 6 to 70 mm² — that covers motor feeds up to roughly 50-60 A depending on duty. Auxiliary and coil terminals accept solid or stranded wire: 2x (0.5-1.5 mm²) or 2x (0.75-2.5 mm²). The auxiliary switch is present on this variant, so you get at least one N.O./N.C. set for feedback or interlocking.

Frequently asked questions

What is the coil voltage range for 3RT2346-1NP30-4AA0?

The coil is rated 175-280 V AC/DC, so it accepts both AC and DC control signals across that range.

What mounting options does this contactor support?

It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 60715, and can be rotated +/-180° on a vertical surface or tilted +/-22.5° forward/backward.

Where can I buy 3RT2346-1NP30-4AA0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3RT2346-1NP30-4AA0