Skip to main content
Siemens 3RT5034-1AR60 — Contactors

Siemens 3RT5034-1AR60 SIRIUS Power Contactor, S2, 55 mm

MPN3RT5034-1AR60

Siemens SIRIUS S2 power contactor, 3RT5034-1AR60, screw-type terminals, 55 mm width, 115 mm depth, 35 mm DIN rail snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT5034-1AR60 — Identification
ParameterValue
Contactor frame sizeS2
3RT5034-1AR60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT5034-1AR60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.42
Rated value @ 50 Hz400 V
3RT5034-1AR60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT5034-1AR60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT5034-1AR60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT5034-1AR60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT5034-1AR60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT5034-1AR60 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT5034-1AR60 — Specifications
ParameterValue
At AC5 000 1/h

Product details

It mounts on 35 mm DIN rail per DIN EN 50022, using either screw fixing or snap-on — the width is 55 mm and depth 115 mm, so it fits a standard 55 mm-wide DIN slot with room for side-by-side mounting without derating.

The 3RT5034-1AR60 is rated for AC-3e duty at 690 V maximum, which is the standard category for squirrel-cage motor starting — switching during running, not stall or inching. The AC-1 resistive load maximum is 1200 operations per hour, while AC-3 motor duty maxes at 1000 ops/h and AC-4 (plugging/reversing) drops to 250 ops/h. That spread tells you this contactor is designed for normal motor start/stop cycles, not high-inertia reversing applications where you'd need a larger frame or a dedicated reversing contactor.

Coil data and wiring

The coil draws 6 A at 24 V rated value, 6 A at 230 V, and 3 A at 400 V — these are inrush or holding currents depending on the AC/DC variant (the 3RT5034-1AR60 uses an AC coil). Terminal wiring accepts 2x (0.75 to 16 mm²) solid or stranded, or 2x AWG 18 to 2. At 40 °C ambient the minimum permissible conductor is 16 mm²; at 60 °C it's 10 mm². That derating matters if you're running the contactor near its thermal limit in a crowded panel.

Mounting flexibility

That gives panel builders flexibility for tight enclosures or angled sub-panels.

Frequently asked questions

Where can I buy 3RT5034-1AR60 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window.

What is the width and depth of 3RT5034-1AR60?

The width is 55 mm and the depth is 115 mm, with a height of 112 mm. It fits a standard 55 mm DIN slot and can be mounted side-by-side without gaps.

What compliance documentation does 3RT5034-1AR60 have?

The part has a substance prohibitance date of 03/01/2017, indicating RoHS compliance. It is rated for pollution degree 3 per IEC standards. For specific UL, CSA, or other certification documents, request them with your RFQ.

Will 3RT5034-1AR60 drop into a panel specified for 3RT5034-1BW40?

Both are S2-size SIRIUS contactors with the same 55 mm width and DIN rail mounting, so the mechanical footprint is identical. The difference is in the coil voltage and terminal type — the 1AR60 uses screw terminals and an AC coil at specific voltage ratings. Verify the coil voltage matches your control circuit before substituting.

MPN