Skip to main content
Siemens 3RT5064-6AM36 — Contactors

Siemens SIRIUS 3RT5064-6AM36 Power Contactor, S10, 1000 V, 8

MPN3RT5064-6AM36

Siemens SIRIUS power contactor, size S10, 3RT5064-6AM36, 1000 V rated insulation voltage, 82 kW at 690 V, screw-type terminals, varistor surge suppression.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT5064-6AM36 — Identification
ParameterValue
Contactor frame sizeS10
3RT5064-6AM36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V82 kW
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT5064-6AM36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz200 ... 220 V
3RT5064-6AM36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT5064-6AM36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 500 A
Short-circuit coordination type 2, fusefuse gL/gG: 400 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT5064-6AM36 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT5064-6AM36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT5064-6AM36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT5064-6AM36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT5064-6AM36 — Specifications
ParameterValue
At AC2 000 1/h

Product details

It handles motor loads up to 82 kW at 690 V and can deliver 164 kW at 400 V when the ambient temperature reaches 60 °C — the derating curve is built into the 60 °C rating, so you don't need to calculate a separate factor for warm panels. The contactor is screw-fixed to the mounting surface, supports side-by-side mounting for dense panel layouts, and accepts wiring up to 150 mm² at 40 °C or 120 mm² at 60 °C. The built-in varistor surge suppressor handles coil transients without an external module.

The 1000 V insulation voltage (rated impulse withstand voltage) means this contactor is suited for 690 V line-to-line systems with adequate clearance — it's not just a 400 V part pushed higher. The AC-3e maximum operating voltage of 1000 V confirms it can switch motor loads on 690 V networks without exceeding the coil or main contact ratings. The 82 kW at 690 V rating is the headline motor-switching figure, but the 164 kW at 400 V and 60 °C is the one that matters for a 400 V panel running hot — it tells you the contactor can deliver full rated power even when the enclosure ambient climbs. The 94 kW at 230 V and 60 °C covers lower-voltage applications without derating. The switching frequency limits are 2000 cycles per hour for AC and DC general use, 750 for AC-1 resistive loads, 500 for AC-3 motor starting, and 130 for AC-4 plugging/reversing — the AC-4 figure is the one that governs inching or jogging applications.

This is a panel-mount contactor, not a DIN-rail snap-on. Side-by-side mounting is permitted, which saves width in multi-contactor motor control centres. The 145 mm width, 210 mm height, and 202 mm depth mean it occupies a standard S10 footprint. If you're replacing an older S10 contactor, the mounting hole pattern and terminal positions should align without panel rework.

No broker or surplus channel required unless lead-time compression demands it.

The substance prohibitance date of 03/01/2017 aligns with RoHS and REACH compliance milestones — the contactor meets the EU RoHS exemption sunset for certain materials.

Frequently asked questions

What are the key dimensions of 3RT5064-6AM36?

Width 145 mm, height 210 mm, depth 202 mm. It uses screw fixing to a vertical surface and supports side-by-side mounting.

What is the maximum motor power this contactor can switch?

82 kW at 690 V, 164 kW at 400 V and 60 °C, and 94 kW at 230 V and 60 °C. The 60 °C ratings mean no additional derating is needed for warm enclosures.

MPN
3RT5064-6AM36