Skip to main content
Siemens 3RT5065-6AB36 — Contactors

Siemens 3RT5065-6AB36 SIRIUS Power Contactor, S10, 197 kW at

MPN3RT5065-6AB36

Siemens SIRIUS 3RT5065-6AB36 power contactor, size S10, screw-type terminals, 197 kW at 400 V 60°C, 1 000 V insulation voltage, varistor surge suppression.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT5065-6AB36 — Identification
ParameterValue
Contactor frame sizeS10
3RT5065-6AB36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V102 kW
Rated value @ 230 V6 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT5065-6AB36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz23 ... 26 V
3RT5065-6AB36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT5065-6AB36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 500 A
Short-circuit coordination type 2, fusefuse gL/gG: 400 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT5065-6AB36 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT5065-6AB36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT5065-6AB36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT5065-6AB36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT5065-6AB36 — Specifications
ParameterValue
At AC2 000 1/h

Product details

SIRIUS S10 Power Contactor for Motor Loads

Its rated motor power at 400 V and 60 °C ambient is 197 kW, with a 1 000 V rated insulation voltage. Side-by-side mounting is permitted, so panel density can be optimized without derating for proximity heat.

Ratings Under Load and Ambient Conditions

Motor power ratings are specified at 60 °C ambient, which is the operating condition that governs real panel performance: 113 kW at 230 V, 197 kW at 400 V, and 340 kW at 690 V. The contactor is rated for AC-1 resistive loads at up to 800 switching cycles per hour, AC-3 motor starting at 700 cycles per hour, and AC-4 plugging/reversing at 130 cycles per hour. Mechanical life is listed at 10 million operations typical. The coil operates on a 23–26 V range at both 50 Hz and 60 Hz, drawing 6 A at 24 V rated value. For control circuit verification: at 110 V the holding current is 1 A, at 220 V it drops to 0.3 A. The integrated varistor suppresses inductive kickback on coil de-energization, which simplifies panel wiring — no external snubber needed for most PLC outputs.

Physical footprint: 210 mm height, 145 mm width, 202 mm depth. The depth dimension is the critical one for enclosure depth selection — at 202 mm, it fits standard 300 mm deep enclosures with clearance for wiring. Side-by-side mounting without spacing is permitted, so multiple S10 contactors can be ganged on a subplate without derating.

Frequently asked questions

What are the key motor power ratings for this contactor?

At 60 °C ambient, the rated motor power is 113 kW at 230 V, 197 kW at 400 V, and 340 kW at 690 V. These are the figures that govern real-world motor switching capability in a warm panel.

Does this contactor include built-in surge suppression?

Yes, the design includes a varistor across the coil for surge suppression. This eliminates the need for an external snubber in most control circuits.

What mounting positions are allowed?

The contactor is designed for screw fixing to a vertical mounting surface. It can be rotated ±90° and tilted ±22.5° front-to-back. Side-by-side mounting is permitted without spacing.

What compliance documentation is available?

The substance prohibition date of March 1, 2017 indicates RoHS compliance. Pollution degree 3 rating confirms suitability for industrial environments. The 1 000 V insulation voltage rating supports standard industrial installation practices.

MPN
3RT5065-6AB36