Siemens 3RT6015-1AP02 — Contactors

Siemens 3RT6015-1AP02 SIRIUS Power Contactor, S00, 690 V AC-

MPN3RT6015-1AP02

Siemens SIRIUS power contactor, size S00, 3RT6015-1AP02, 690 V AC-3 rated, 6 kW at 230 V, 10.5 kW at 400 V, 18 kW at 690 V, screw terminals, DIN rail snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT6015-1AP02 — Identification
ParameterValue
Contactor frame sizeS00
3RT6015-1AP02 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT6015-1AP02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT6015-1AP02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT6015-1AP02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
Short-circuit coordination type 2, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT6015-1AP02 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT6015-1AP02 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT6015-1AP02 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT6015-1AP02 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RT6015-1AP02 — Specifications
ParameterValue
At AC10 000 1/h

Product details

It mounts via screw and snap-on onto 35 mm DIN rail per DIN EN 50022, and its 45 mm width and 73 mm depth keep the panel fill factor tight — three of these sit in the space of a single 4-pole breaker.

Rated AC-3 at 690 V maximum, this contactor handles motor switching up to 6 kW at 230 V, 10.5 kW at 400 V, and 18 kW at 690 V — all at 60 °C ambient. The AC-3 duty cycle maxes at 750 operations per hour, so it's fine for frequent start-stop on conveyors or pumps, but not for jogging or inching at high rates. Coil draw is 0.25 A at both 50 Hz and 60 Hz, which is low enough that a standard 24 VDC PLC output can drive it through an interposing relay without a separate power supply for the coil bus.

Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded copper. Side-by-side mounting is permitted, which keeps multi-contactor groups dense.

MPN
3RT6015-1AP02