Siemens 3RT6017-1AR61 SIRIUS Contactor, 13 kW at 400 V, Size

MPN3RT6017-1AR61

Siemens SIRIUS 3RT6017-1AR61, Size S00 power contactor, screw-type terminals, 45 mm width, 13 kW at 400 V 60 °C, AC-3 duty.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT6017-1AR61 — Identification
ParameterValue
Contactor frame sizeS00
3RT6017-1AR61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT6017-1AR61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz400 V
3RT6017-1AR61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT6017-1AR61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
Short-circuit coordination type 2, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT6017-1AR61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT6017-1AR61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT6017-1AR61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT6017-1AR61 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RT6017-1AR61 — Specifications
ParameterValue
At AC10 000 1/h

Product details

Rated for AC-3 motor duty at 400 V and 60 °C ambient, it handles 13 kW — enough for a medium pump, fan, or conveyor drive in a continuous-process mill. The 690 V insulation voltage (rated value) keeps it comfortable in 400 V or 480 V systems without derating creepage distances.

Motor ratings that survive the steam and the chemicals

At 60 °C ambient — common inside a non-ventilated MCC bucket or a pulp-mill motor control centre — the contactor still delivers 13 kW at 400 V and 22 kW at 690 V. That's not a best-case number at 40 °C; it's the rating that matters when the panel is hot and the load is continuous.

Maximum mechanical switching rate is 10 000 operations per hour, but that's the mechanism limit. For AC-3 motor starts the practical ceiling is 750 1/h, and for AC-4 (plugging / inching) it drops to 250 1/h. If your application cycles faster than that — say a high-speed indexing conveyor — step up to a larger frame or a dedicated reversing contactor pair. The 24 V DC coil draws 6 A inrush (rated value), settling to a holding current around 0.25 A at 50/60 Hz. At 230 V the coil draw is 10 A inrush. Verify your control transformer and fuse sizing: a 24 V DC supply feeding multiple contactors needs headroom for simultaneous pickup.

Frequently asked questions

How do I get current pricing and availability for 3RT6017-1AR61?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through our independent distribution network — we source to order against your BOM line.

Will 3RT6017-1AR61 drop into a panel specified around 3RT6017-1KF42 without rewiring?

Yes — both are Size S00 contactors with the same 45 mm width and DIN-rail mounting footprint. The 3RT6017-1AR61 uses screw-type terminals; the 1KF42 uses spring-cage terminals. The physical layout and rail position are identical, so no panel rework is needed. The wiring method differs (screw vs spring), but the terminals accept the same conductor sizes.

What compliance documentation does Siemens provide for 3RT6017-1AR61?

The contactor carries RoHS compliance dated 2012-05-01 and is designed to meet IEC 60947-4-1. Siemens provides a declaration of conformity, material declarations, and UL/CSA file information through their standard documentation portal.

MPN