Siemens 3RT6018-1AK61 — Contactors

Siemens 3RT6018-1AK61 SIRIUS Contactor, S00, 13 kW at 400 V

MPN3RT6018-1AK61

Siemens SIRIUS power contactor, size S00, 3RT6018-1AK61, 13 kW at 400 V 60°C, screw-type terminals, 45 mm wide, 73 mm deep.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT6018-1AK61 — Identification
ParameterValue
Contactor frame sizeS00
3RT6018-1AK61 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT6018-1AK61 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT6018-1AK61 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT6018-1AK61 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
Short-circuit coordination type 2, fusegL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT6018-1AK61 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT6018-1AK61 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT6018-1AK61 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT6018-1AK61 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RT6018-1AK61 — Specifications
ParameterValue
At AC10 000 1/h

Product details

The Siemens 3RT6018-1AK61 is a SIRIUS power contactor in the S00 frame size — the smallest of the SIRIUS contactor family, sized for motor loads up to 13 kW at 400 V (at 60 °C ambient) and 22 kW at 690 V. It switches AC-3 duty up to 690 V, which covers the vast majority of three-phase induction motors in industrial panels. The screw-type terminals on the main circuit accept up to 4 mm² conductors, and the coil draws 0.24 A at 50 Hz, 0.25 A at 60 Hz — a standard 24 VAC/DC coil that any 24 V control transformer can drive.

At 45 mm wide and 73 mm deep, it takes up one standard 45 mm slot on the rail — same footprint as any S00 contactor.

The motor power ratings are given at 60 °C ambient — a realistic panel temperature. At 400 V, it's rated 13 kW; at 230 V, 7.5 kW; at 690 V, 22 kW. These are AC-3 (squirrel-cage motor switching) values, which is the duty cycle that matters for most conveyor, pump, and fan loads. The AC-1 resistive rating (heater or lighting loads) is higher, but for motor duty, the AC-3 figure governs. The contactor is rated for 30 million mechanical operations typical, so it outlasts the machine in most applications.

Pollution degree 3 (industrial environment, conductive pollution). RoHS compliance date listed as 05/01/2012 — it's been RoHS-compliant for over a decade. The insulation voltage is rated 690 V, matching the maximum switching voltage.

Frequently asked questions

Where can I buy 3RT6018-1AK61 and what is the lead time?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

Will 3RT6018-1AK61 drop into a panel specified around 3RT6017-1KF42 without rewiring?

Both are S00 frame contactors with the same 45 mm width and DIN-rail mounting, so the mechanical fit and terminal layout are identical. The main difference is the coil voltage — the 3RT6018-1AK61 uses a 24 VAC/DC coil (0.24 A at 50 Hz), while the 3RT6017-1KF42 uses a different coil voltage. If the control voltage matches, it's a direct swap; if not, the coil circuit needs re-termination.

What are the key dimensions of 3RT6018-1AK61?

Width 45 mm, height 57.5 mm, depth 73 mm. It occupies one standard 45 mm DIN-rail slot.