Siemens 3RT6926-5AN21 — Contactors

Siemens 3RT6926-5AN21 SIRIUS Magnet Coil, 220 V AC, Size S0

MPN3RT6926-5AN21

Siemens SIRIUS 3RT6926-5AN21 magnet coil, 220 V AC 50/60 Hz, for size S0 contactors, screw terminal, 10.5 VA typical holding power.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT6926-5AN21 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RT6926-5AN21 — Other specifications
ParameterValue
At 60 Hz0.85 ... 1.1
At 60 Hz rated value220 V
Power loss [V∙A] of magnet coil at AC typical10.5 V·A

Product details

It's the part that fails when the coil burns open or shorts, and swapping it is a lot faster than pulling the whole contactor off the DIN rail. Typical holding power draw is 10.5 VA — that's the steady-state load on the control transformer once the contactor is sealed in. The coil draw at pickup is higher (the inrush to pull the armature in), but the 10.5 VA figure is what the control circuit sees continuously. Make sure your transformer or PLC output can handle the inrush peak; the holding VA is well within a standard 24 VA control transformer's capacity.

The coil is designed for screw-terminal connection — two terminals for the control voltage, no polarity on AC. It snaps onto the contactor's magnet system without tools; the contactor stays on the DIN rail. That's the field-service angle: you can swap this coil in the panel without pulling wires from the main power circuit. Size S0 is a common contactor frame in the SIRIUS line (covers motor ratings roughly up to 18.5 kW at 400 V AC-3). If you're replacing a coil on an existing S0 contactor, verify the contactor's own order code — the coil voltage must match the existing control circuit.

Frequently asked questions

What is the coil voltage and frequency rating?

220 V AC at both 50 Hz and 60 Hz. The control supply voltage type is AC only — not suitable for DC control circuits.

What is the typical power consumption of this coil?

The typical holding power is 10.5 VA at AC. Pickup inrush is higher (not listed here), so size your control transformer for the inrush, not just the holding VA.

Will this coil fit a contactor that originally used 3RT1016-1AN22?

Not directly. The 3RT1016-1AN22 is a complete size S00 power contactor, not a coil. The 3RT6926-5AN21 coil is for size S0 contactors. The physical magnet system and mounting differ between S00 and S0 frames. You need to check the contactor's size marking before ordering.

MPN
3RT6926-5AN21