Siemens 3RT7014-1AB02 — Contactors

Siemens 3RT7014-1AB02 Contactor, Size S00, 24 V Coil, 3-Pole

MPN3RT7014-1AB02

Siemens SIRIUS 3RT7014-1AB02 contactor, size S00, 3-pole, 24 V 50/60 Hz coil, screw terminals, 45 mm width, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT7014-1AB02 — Identification
ParameterValue
Contactor frame sizeS00
3RT7014-1AB02 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7014-1AB02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz24 V
3RT7014-1AB02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7014-1AB02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 35 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7014-1AB02 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT7014-1AB02 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7014-1AB02 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

Size S00 — the 45 mm frame that fits tight panels

The 3RT7014-1AB02: At 45 mm wide and 72 mm deep, this S00-frame contactor slides into the same DIN-rail footprint as other S00 accessories — auxiliary contact blocks, surge suppressors, and the matching overload relay all snap on without stealing extra rail space. That covers most panel layouts without derating.

That low holding draw means the PLC output driving it sees minimal steady-state load — useful when running a bank of contactors from a single 24 VDC supply. Main and auxiliary circuits use screw-type terminals. Surge voltage resistance is 6 kV — enough for industrial environments with pollution degree 3.

Switching rate and fuse coordination — the real-world limits

Maximum switching rate in AC-3 duty is 750 operations per hour, and in AC-4 it drops to 250 per hour. AC-3e matches the AC-3 rate at 750 ops/h. For a conveyor that cycles every 30 seconds, that's well within the envelope; for a fast-indexing pick-and-place, watch the AC-4 limit. Fuse coordination: type 2 (no damage to the contactor on a short circuit) requires a 20 A gL/gG NH 3NA fuse. Type 1 (contactor may need replacement after a fault) allows a 35 A fuse. This matters when designing the upstream MCCB or fuse selection for selectivity. Shock resistance is 9.8g at 5 ms and 5.9g at 10 ms — adequate for most industrial panels but not for heavy rotating machinery mounted directly on the machine frame.

Lifecycle and sourcing — active line, quoted to order

No stock-holding claim is made — each order is quoted individually.

Frequently asked questions

Will 3RT7014-1AB02 drop into a panel designed for 3RT2028-1BB40?

No — the 3RT2028-1BB40 is a larger frame size (S2 or S3 class) with a different footprint. The 3RT7014-1AB02 is size S00 at 45 mm wide, while the 3RT2028-1BB40 is physically larger. They are not drop-in interchangeable; a panel redesign or adapter plate would be needed.

MPN
3RT7014-1AB02