Siemens 3RT7014-1AQ02 Contactor, S00, 3-Pole, 6 A at 230 V

MPN3RT7014-1AQ02

Siemens SIRIUS 3RT7014-1AQ02, size S00 contactor, 3-pole, 3 NO main contacts, AC-3 rated 6 A at 230 V, 3 A at 400 V, 1 A at 690 V, screw terminals, IP20, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT7014-1AQ02 — Identification
ParameterValue
Contactor frame sizeS00
3RT7014-1AQ02 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7014-1AQ02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz380 V
3RT7014-1AQ02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7014-1AQ02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 35 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7014-1AQ02 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7014-1AQ02 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7014-1AQ02 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RT7014-1AQ02 is a size S00 contactor with three normally-open main contacts, rated for AC-3 duty at 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. The AC-3 rating means it's designed for switching squirrel-cage motors — the most common induction motor load in industrial panels — up to those currents. The 690 V rating covers 480 V and 575 V line supplies common in North American and marine installations. The control coil is AC-powered. Closing power draw is 0.8 W DC; holding power drops to 0.27 W DC. That low holding power means the coil runs cool in a sealed panel — less heat to manage in a crowded DIN-rail row.

The S00 footprint — 45 mm wide, 57.5 mm tall, 72 mm deep — fits standard 45 mm-wide DIN-rail slots. IP20 on the front and at the terminals — finger-safe for a closed panel, but not washdown-rated. Keep it inside a cabinet.

Insulation voltage rated 690 V; surge voltage resistance 6 kV. For type 2 coordination (no-weld after fault), the recommended backup fuse is a 20 A gL/gG NH 3NA. For type 1 coordination (allow weld but clear fault), a 35 A gL/gG NH 3NA. That's the fuse size the panel designer needs to spec upstream. Maximum switching frequency: 750 operations per hour at AC-3, 250 at AC-4. AC-4 is plugging/reversing duty — harder on the contacts, so the lower rate reflects that. If your application cycles faster than 250/h under reversing loads, this contactor will overheat.

Frequently asked questions

How do I get current pricing and availability for 3RT7014-1AQ02?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; pricing and stock are confirmed at quote time.

Will 3RT7014-1AQ02 drop into a panel that was specified around 3RT6015-1AF02 without rewiring?

Both are size S00 contactors with the same 45 mm width and screw-terminal main/auxiliary connections, so the mechanical footprint and terminal layout are compatible. The 3RT7014-1AQ02 is AC-coil only; if the original panel used a DC-coil variant, the control circuit wiring differs and the coil supply must be verified.

What is 3RT7014-1AQ02's listed depth (72 mm) on this component line?

The depth is 72 mm. That's the dimension from the DIN-rail mounting surface to the front of the contactor — important for enclosure depth clearance.

What is 3RT7014-1AQ02's listed width (45 mm) on this component line?

The width is 45 mm, which is the standard single-module width for size S00 contactors on 35 mm DIN rail.