Siemens 3RT7014-1AV02 — Contactors

Siemens 3RT7014-1AV02 Contactor, S00, 3-pole, AC Coil, 6 A a

MPN3RT7014-1AV02

Siemens SIRIUS 3RT7014-1AV02, Size S00 contactor, 3-pole, AC coil, screw terminals, 6 A at 230 V AC-3, 45 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT7014-1AV02 — Identification
ParameterValue
Contactor frame sizeS00
3RT7014-1AV02 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7014-1AV02 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz400 V
3RT7014-1AV02 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7014-1AV02 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 35 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7014-1AV02 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7014-1AV02 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7014-1AV02 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

Siemens 3RT7014-1AV02 — S00 Contactor, AC Coil, 3-Pole

Rated operational current in AC-3 duty is 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V — that's the motor-switching current for squirrel-cage motors. The AC-3 switching frequency maxes out at 750 operations per hour; for AC-4 (inching/plugging duty) it's 250 per hour, so keep that in mind if the application does frequent reversing. Coil draws 0.8 W on pickup and holds at 0.27 W DC — that's the holding power once the armature seats. The AC control voltage means you'll need to verify the coil matches your control transformer tap; no DC conversion inside this unit.

Side-by-side mounting is allowed, so no derating for zero-gap stacking. That helps when the gland plate or busbar layout forces an odd angle. Terminals are screw-type for both main and auxiliary circuits, accepting 2x (0.5…1.5 mm²) solid/stranded or 2x (0.75…2.5 mm²) with ferrules. Pollution degree 3 — suitable for control panels in industrial environments where some conductive dust is present.

Protection and Coordination

For Type 2 coordination (contactor remains fully functional after a fault), use gL/gG 20 A. Both ratings call for NH 3NA fuses.

Frequently asked questions

Where can I buy 3RT7014-1AV02 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is 3RT7014-1AV02's depth and width?

Depth is 72 mm, width is 45 mm, height is 57.5 mm. It occupies a standard 45 mm DIN-rail slot.

Will 3RT7014-1AV02 drop into a panel wired for a 3RT6018-1AB02?

Both are S00 frame contactors with the same 45 mm width and DIN-rail footprint, so the mechanical fit is the same. The key difference is the coil voltage — verify the 3RT7014-1AV02's AC coil matches your control voltage before swapping.