Siemens 3RT7016-1AG01 Contactor, Size S00, 3-Pole, 690 V AC-

MPN3RT7016-1AG01

Siemens SIRIUS 3RT7016-1AG01 contactor, Size S00, 3-pole, AC-3 rated 690 V, screw-type terminals, IP20 finger-safe front and terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT7016-1AG01 — Identification
ParameterValue
Contactor frame sizeS00
3RT7016-1AG01 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7016-1AG01 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz36 V
3RT7016-1AG01 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7016-1AG01 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 35 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 20 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7016-1AG01 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7016-1AG01 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7016-1AG01 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RT7016-1AG01 is a 3-pole contactor in the S00 frame size, rated for AC-3 duty up to 690 V maximum operating voltage. The S00 frame keeps the footprint compact at 45 mm wide, 57.5 mm tall, and 72 mm deep — sized for DIN-rail enclosures where panel space is tight.

Side-by-side mounting is permitted, so multiple contactors can pack tightly on the rail without derating for proximity heat.

The AC-3 rated operating current at 400 V is 3 A, and at 230 V it is 6 A — these are the currents it can make and break under motor starting conditions (inrush up to 6-8x FLA). The main contacts are 3 NO (normally open) with no NC main contacts — standard for a motor-starting contactor. The auxiliary switch is available as a product extension, and the contact reliability is rated for PLC-level control (17 V, 5 mA), so it can drive a logic input directly without a separate interface relay.

Coil and control supply

The control supply voltage is AC type. The closing power of the magnet coil at DC is 0.8 W, and the holding power drops to 0.27 W — the lower holding power means less heat dissipated in the panel during continuous operation, which matters when contactors are ganged side-by-side. The coil can handle 50/60 Hz at 36 V rated value. The shock resistance is rated at 9.8g for 5 ms and 5.9g for 10 ms sine pulse — sufficient for most industrial machinery but worth checking if the contactor is mounted on a vibrating conveyor or press.

No last-time-buy or allocation risk is indicated.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, height is 57.5 mm, depth is 72 mm. It mounts on 35 mm DIN rail per EN 50022.

What is the maximum motor voltage this contactor can switch?

The AC-3 rated operating voltage maximum is 690 V, suitable for three-phase induction motors up to that line voltage.

Does this contactor have screw terminals or spring-cage terminals?

It has screw-type terminals for both the main current circuit and the auxiliary/control circuit. The terminals accept 2x (0.5 to 1.5 mm²) solid or stranded wire, or 2x (0.75 to 2.5 mm²) with ferruled ends.

Can this contactor be mounted side-by-side with others without derating?

Yes, side-by-side mounting is permitted. The low holding power of 0.27 W helps keep heat buildup manageable in tight groupings.

What fuse rating is required for type 2 coordination?

For type of coordination 2, the required fuse is gL/gG NH 3NA rated 20 A. For type of coordination 1, the rating is 35 A.