Siemens 3RT7026-1AL25 SIRIUS Contactor, 3-Pole, AC-3 690 V,

MPN3RT7026-1AL25

Siemens SIRIUS 3RT7026-1AL25, size S0, 3-pole power contactor, 690 V AC-3 rated, 55 mm width, screw terminals, IP20 front and terminal protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT7026-1AL25 — Identification
ParameterValue
Contactor frame sizeS0
3RT7026-1AL25 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7026-1AL25 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz230 V
3RT7026-1AL25 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7026-1AL25 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 80 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7026-1AL25 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Side-by-side mountingYes
3RT7026-1AL25 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7026-1AL25 — Mechanical
ParameterValue
Width55 mm
Height85.5 mm
Depth91 mm

Product details

Siemens SIRIUS 3RT7026-1AL25 — 3-Pole Power Contactor, Size S0

Mounting is via screw and snap-on onto 35 mm DIN rail per DIN EN 50022, with ±180° rotation and ±22.5° tilt allowed on vertical surfaces — useful for tight enclosure layouts. Coil consumption is 0.72 W during pick-up and 0.24 W holding at DC — low enough to keep heat rise minimal in a crowded DIN rail row. The screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 2.5 mm²) solid or finely stranded wire with ferrules, matching common panel-wiring practice.

AC-3 Motor Switching and Coordination

For motor starting duty (AC-3), the contactor is rated at 690 V maximum, with a rated operational current that depends on the applied voltage: 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. These values determine the maximum induction motor current it can switch under Category AC-3 — the load governs which column applies. The switching frequency is 800 operations per hour for AC-3 and AC-3e, dropping to 250 per hour for AC-4 (plugging/inching) duty. The impulse withstand voltage is 6 kV, and the pollution degree is 3 (controlled environment, not sealed).

Dimensions, Mounting, and Auxiliary Options

The S0 frame occupies 55 mm width, 85.5 mm height, and 91 mm depth — a standard footprint for this size class. The product accepts auxiliary switch blocks as a field-addable extension, so a single catalog number covers the base contactor and you add the aux contacts separately.

Frequently asked questions

What are the key ratings for the 3RT7026-1AL25?

It is a 3-pole contactor rated for AC-3 duty at 690 V maximum, with switching frequencies of 800 ops/h for AC-3 and 250 ops/h for AC-4. The S0 frame size is 55 mm wide, 85.5 mm tall, and 91 mm deep. Coil consumption is 0.72 W pick-up, 0.24 W hold at DC.