Skip to main content
Siemens 3RT7027-1AF00 — Contactors

Siemens 3RT7027-1AF00 Contactor, S0, 3-Pole, 690V AC-3, 45mm

MPN3RT7027-1AF00

Siemens SIRIUS 3RT7027-1AF00, size S0, 3-pole contactor, 690 V AC-3 rated operational voltage, 45 mm width, screw-type terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT7027-1AF00 — Identification
ParameterValue
Contactor frame sizeS0
3RT7027-1AF00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7027-1AF00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT7027-1AF00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7027-1AF00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 125 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 50 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7027-1AF00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7027-1AF00 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7027-1AF00 — Mechanical
ParameterValue
Width45 mm
Height85.5 mm
Depth91 mm

Product details

The 3RT7027-1AF00: The AC-3 rated operational voltage of 690 V maximum means this contactor can switch three-phase motor loads up to that line voltage — common in 400 V and 690 V industrial networks. For DC-13 duty at 220 V, the rated operational current is 0.3 A, so it handles moderate DC loads like solenoid valves or DC brake coils within that limit. For type 1 and type 2 coordination, the recommended backup fuse is a gL/gG NH 3NA: 50 A for type 2, and 125 A for type 1. This is critical when sizing the short-circuit protection device upstream — using a smaller fuse than specified may cause the contactor to weld under fault.

Side-by-side mounting is permitted, so multiple contactors can be ganged without additional spacing — useful for compact motor control centers. Dimensions: 85.5 mm height, 45 mm width, 91 mm depth. The 45 mm width occupies two 22.5 mm module spaces on a DIN rail — a standard footprint for S0 contactors. IP20 on the front and terminals means it is touch-safe but not sealed against water; install inside a panel with at least IP54 enclosure for washdown areas.

MPN
3RT7027-1AF00