Siemens 3RT7037-1AH00 Contactor, S2 Size, 3-Pole, 690 V AC-3

MPN3RT7037-1AH00

Siemens SIRIUS 3RT7037-1AH00, size S2 contactor, 3-pole, 3 NO main contacts, AC-3 rated to 690 V, screw terminals, IP20 front, DIN EN 50022 rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT7037-1AH00 — Identification
ParameterValue
Contactor frame sizeS2
3RT7037-1AH00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7037-1AH00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.36
Rated value @ 50 Hz42 V
3RT7037-1AH00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7037-1AH00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 160 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 100 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7037-1AH00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7037-1AH00 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7037-1AH00 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm

Product details

The control supply is AC only, so don't plan on wiring a DC coil into this unit. It fastens with screws or snaps onto a 35 mm DIN rail per EN 50022, and the mounting position allows ±180° rotation on a vertical surface plus ±22.5° tilt forward or back. That's a lot of flexibility for tight panel layouts. Keep that in mind for touch-safe installation requirements.

Three main poles, all normally open, handle the power circuit. The AC-3 maximum operating voltage is 690 V, so it'll switch a 400 V motor without issue. For DC-13 loads at 220 V, the rated current drops to 0.3 A — that's a solenoid or brake coil, not a motor. The auxiliary contact reliability is specified as acceptable for PLC control at 17 V, 5 mA. That means the contacts are designed to switch low-energy signals without the oxidation problems that plague standard power contacts on PLC inputs. Fuse coordination is specified: for type 2 coordination, use a 100 A gL/gG NH 3NA fuse; for type 1, a 160 A fuse of the same class. That's the short-circuit protection the manufacturer expects for this contactor size. The magnet coil draws 0.79 W on closing and holds at 0.36 W DC. That's a low holding power, which keeps the coil cool in continuous-duty applications like conveyors or pumps.

Dimensions are 55 mm wide, 112 mm tall, and 115 mm deep. That's the S2 frame footprint — it'll sit next to other SIRIUS S2 components on the same DIN rail without extra spacing, since side-by-side mounting is allowed. Main and auxiliary/control circuits both use screw-type terminals. The wire range accepts 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with or without ferrules. That covers standard control wiring up to about 14 AWG. The contactor accepts an auxiliary switch block as a product extension, so you can add feedback contacts for PLC status monitoring without replacing the whole unit.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 55 mm, height 112 mm, depth 115 mm. It mounts on a 35 mm DIN rail per EN 50022 and allows side-by-side mounting without gaps.

What's the AC-3 voltage rating and what loads does it suit?

AC-3 maximum operating voltage is 690 V, so it handles standard three-phase motor loads up to that line voltage. For DC-13 loads at 220 V, the rated current is 0.3 A.

What short-circuit protection does this contactor need?

For type 2 coordination, use a 100 A gL/gG NH 3NA fuse; for type 1 coordination, a 160 A fuse of the same class.

Can I add auxiliary contacts to this unit?

Yes, the contactor accepts an auxiliary switch block as a product extension, allowing feedback contacts for status monitoring.

MPN
3RT7037-1AH00