Siemens 3RT7037-1AL20 — Contactors

Siemens 3RT7037-1AL20 Contactor, S2 Size, 3-Pole, AC Coil 23

MPN3RT7037-1AL20

Siemens SIRIUS 3RT7037-1AL20, Size S2 contactor, 3-pole, 3 NO main contacts, AC coil 230 V 50/60 Hz, screw-type terminals, IP20 front, IP00 terminal area.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT7037-1AL20 — Identification
ParameterValue
Contactor frame sizeS2
3RT7037-1AL20 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7037-1AL20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.36
Rated value @ 50 Hz230 V
3RT7037-1AL20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7037-1AL20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 160 A
Short-circuit coordination type 2, fusegL/gG NH 3NA: 100 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7037-1AL20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT7037-1AL20 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7037-1AL20 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm

Product details

The Siemens 3RT7037-1AL20 is a Size S2 contactor with three normally-open main contacts and an AC coil rated for 230 V at both 50 Hz and 60 Hz. The screw-type terminals on both the main and auxiliary/control circuits make it a straightforward replacement in existing panels — no retooling for cage-clamp or ring-tongue.

Dimensions are 112 mm high, 55 mm wide, 115 mm deep — the S2 footprint. Accepts 2 × (0.5 … 1.5 mm²) solid or stranded, or 2 × (0.75 … 2.5 mm²) with ferruled ends. The auxiliary contact block is field-addable — the product extension for auxiliary switches is supported.

Coil and control considerations

The AC coil draws 0.36 A at 50 Hz, 0.38 A at 60 Hz. Closing power is 0.76 W DC holding power — a low steady-state draw that keeps the coil cool in continuous duty. Auxiliary contacts are rated for PLC-level signals: the contact reliability spec says they're acceptable for PLC control at 17 V, 5 mA.

For type of coordination 2 (limited short-circuit damage), the required upstream fuse is a gL/gG NH 3NA: 100 A. For type of coordination 1 (no damage to the contactor, but may need contact replacement), the fuse is gL/gG NH 3NA: 160 A. These are the fuse ratings the manufacturer specifies — use them to size the branch circuit protection. Mechanical endurance is not explicitly listed, but the switching frequency limits are: 800 operations per hour maximum at AC-3 (motor starting), 250 operations per hour at AC-4 (plugging/inching). Shock resistance is 15g for 5 ms and 8g for 10 ms sine pulse — enough for most industrial machinery but not for high-g mobile applications.

Frequently asked questions

What is the depth of 3RT7037-1AL20?

The depth is 115 mm.

What is the width of 3RT7037-1AL20?

The width is 55 mm.

MPN
3RT7037-1AL20