Siemens 3RT7045-1AB00 Contactor, S3, 3-Pole, 24V AC Coil

MPN3RT7045-1AB00

Siemens SIRIUS S3 contactor, 3RT7045-1AB00, 3-pole main contacts, 24 V AC coil, screw terminals, IP20 front / IP00 terminal, 139 x 70 x 148 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT7045-1AB00 — Identification
ParameterValue
Contactor frame sizeS3
3RT7045-1AB00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7045-1AB00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz24 V
3RT7045-1AB00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7045-1AB00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 200 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7045-1AB00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT7045-1AB00 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7045-1AB00 — Mechanical
ParameterValue
Width70 mm
Height148 mm
Depth139 mm

Product details

The Siemens 3RT7045-1AB00 is a Size S3 contactor from the SIRIUS family — three main poles, normally open, rated for AC-3 motor switching up to 690 V. The coil pulls in on 24 V AC and holds at 0.26 W DC holding power, so the control transformer sizing is modest. It lands on a 35 mm or 75 mm standard mounting rail via screw or snap-on fastening; the mounting position allows ±180° rotation on a vertical surface and ±22.5° tilt forward or backward, which gives panel builders flexibility when laying out a crowded door or sub-panel.

Switching frequency and duty limits

The maximum switching rate is 800 operations per hour under AC-3 duty and 250 operations per hour under AC-4. That 250 ops/h limit under AC-4 (plugging / inching) is the one that governs in high-cycle reversing or jogging applications — exceed it and the contactor overheats. For a standard conveyor start or pump run, the AC-3 figure gives comfortable headroom.

Coordination and environmental fit

With Type 1 coordination the upstream fuse is a 200 A gL/gG NH 3NA. The surge voltage withstand is 6 kV, so it holds up in installations with moderate lightning or switching transients on a 400 V supply. Installation altitude is limited to 2 000 m above sea level without derating.

Auxiliary contacts and PLC compatibility

For DC-13 loads at 220 V the auxiliary circuit carries 0.3 A.

Frequently asked questions

What is 3RT7045-1AB00's panel footprint?

The dimensions are 139 mm depth, 70 mm width, and 148 mm height. It mounts via screw or snap-on onto 35 mm or 75 mm standard mounting rail.

Will 3RT7045-1AB00 drop into a panel specified around 3RT6018-1AB02?

Not without checking the physical envelope. The 3RT7045-1AB00 is a Size S3 frame (139 x 70 x 148 mm), while the 3RT6018-1AB02 is a smaller S0 frame. The mounting rail and screw terminals are the same style, but the S3 occupies more DIN space and may conflict with adjacent devices or gland plates in a panel originally laid out for S0.

Where can I buy 3RT7045-1AB00?

The contactor is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.