Siemens 3RT7046-1AV00 — Contactors

Siemens 3RT7046-1AV00 Size S3 Contactor, 3-Pole, 690V AC-3,

MPN3RT7046-1AV00

Siemens SIRIUS 3RT7046-1AV00 Size S3 contactor, 3-pole, AC-3 rated 690 V max, screw-type terminals, IP20 front, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT7046-1AV00 — Identification
ParameterValue
Contactor frame sizeS3
3RT7046-1AV00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
3RT7046-1AV00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.27
Rated value @ 50 Hz400 V
3RT7046-1AV00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliabilityacceptability for PLC control (17 V, 5 mA)
3RT7046-1AV00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegL/gG NH 3NA: 200 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT7046-1AV00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT7046-1AV00 — Environmental
ParameterValue
Operating temperature range-10 ... +55 °C
Storage temperature range-25 ... +70 °C
Installation altitude, max.2 000 m
3RT7046-1AV00 — Mechanical
ParameterValue
Width70 mm
Height148 mm
Depth139 mm

Product details

Siemens 3RT7046-1AV00 — Size S3 Contactor, 3-Pole, Screw Terminals

The Siemens 3RT7046-1AV00 is a Size S3 contactor from the SIRIUS family, with three normally open main contacts and three poles for the main current circuit.

The AC-3e maximum switching frequency of 800 operations per hour sets a thermal limit on how often you can cycle it under motor load; exceed that and the internal heat buildup will shorten contact life. For the more severe AC-4 duty (plugging, inching, reversing), the maximum drops to 250 operations per hour. The insulation voltage is also rated at 690 V, and surge voltage resistance is 6 kV — that 6 kV figure is the impulse withstand level for overvoltage category III, so it can handle typical switching transients on a 400 V industrial network without flashover.

The contactor measures 70 mm wide, 148 mm high, and 139 mm deep. It snaps onto 35 mm or 75 mm DIN rails via the integrated clip, and can also be screw-mounted. Side-by-side mounting is allowed with no derating gap required, which simplifies panel layout. The screw terminals accept 2× (0.5…1.5 mm²) solid or stranded, or 2× (0.75…2.5 mm²) finely stranded with core end processing. For type 1 coordination, the recommended upstream fuse is a gL/gG NH 200 A — that is the fuse that will clear a bolted fault before the contactor welds shut.

Frequently asked questions

What are the key dimensions for panel planning?

Width is 70 mm, height is 148 mm, and depth is 139 mm. It mounts on 35 mm or 75 mm DIN rail via snap-on or screw fixing.

What is the AC-3 voltage rating and switching frequency?

The AC-3 rated voltage maximum is 690 V. The maximum switching frequency under AC-3 duty is 800 operations per hour, dropping to 250 operations per hour for AC-4 duty.

Can this contactor be mounted side-by-side with others?

Yes, side-by-side mounting is permitted, which means no spacing gap is required between units on the same DIN rail.

What type of coordination fuse is specified?

For type 1 coordination, the recommended upstream fuse is a gL/gG NH 200 A.

MPN
3RT7046-1AV00