3RU1116-1DB0-ZW95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU1116-1DB0-ZW95 — Protection & Trip
ParameterValue
Overload current setting range2.2 ... 3.2 A
Trip classCLASS 10
3RU1116-1DB0-ZW95 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W
3RU1116-1DB0-ZW95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU1116-1DB0-ZW95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RU1116-1DB0-ZW95 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance8g / 10 ms
3RU1116-1DB0-ZW95 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth78 mm
3RU1116-1DB0-ZW95 — Specifications
ParameterValue
Type Of ProtectionDMT 98 ATEX G 001

Product details

The Siemens 3RU1116-1DB0-ZW95 is a SIRIUS thermal overload relay in the S00 frame size, designed for direct contactor mounting to protect 3-phase motor circuits against overload and phase failure. The relay is finger-safe (IP20 on the front) and carries ATEX approval (DMT 98 ATEX G 001) for use in potentially explosive gas atmospheres, so it can be deployed in Zone 2 or Zone 22 applications when paired with an appropriate contactor.

Mounts directly onto a SIRIUS S00 contactor without additional hardware — no DIN rail needed. The mounting position allows a vertical surface with ±135° rotation and ±45° tilt front-to-back, giving panel layout flexibility. This zero-clearance top/bottom mounting means the relay can be stacked tight against other components in a crowded enclosure, but the 6 mm side gap must be maintained for heat dissipation.

Wiring and conductor compatibility

Main and auxiliary circuit terminals accept solid or finely stranded conductors with core-end processing: 2× (0.5... 1.5 mm²) and 2× (0.75... 2.5 mm²) per clamp. For AWG, the auxiliary contacts accept 2× (20... 16) and 2× (18... 14). This gives flexibility for both European metric and North American wiring practices. The screw-type terminals are the same as the main circuit terminals, so the same screwdriver and torque setting work across all connections — no tool change for the auxiliary wiring.

Frequently asked questions

How do I get current pricing and availability for 3RU1116-1DB0-ZW95?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels — no automated stock figure is displayed because the supply position changes daily.

What is the closest functional second-source to 3RU1116-1DB0-ZW95?

The 3RU2116-1FC1 is a larger-frame SIRIUS overload relay (S2 size) that shares the same CLASS 10 trip characteristic and screw-terminal design. It will not drop into an S00 contactor mount without changing the contactor to an S2 frame, so panel rewiring is required. For a direct form-fit-function swap within the S00 frame, stay with the 3RU1116 series.

What compliance documentation does this relay carry?

The relay carries ATEX approval DMT 98 ATEX G 001 for gas atmospheres, IP20 finger-safe touch protection, and a substance prohibitance date of 07/01/2006 indicating RoHS compliance. The reference code per IEC 81346-2 is F (protective device).

MPN
3RU1116-1DB0-ZW95