Siemens 3RU1116-1GB0-ZW98 — Overload Relays

Siemens 3RU1116-1GB0-ZW98 SIRIUS Thermal Overload Relay, Cla

MPN3RU1116-1GB0-ZW98

Siemens SIRIUS 3RU1116-1GB0-ZW98 thermal overload relay, Size S00, 3-pole, Class 10, screw terminals, 24 V 1 A control circuit, ATEX.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU1116-1GB0-ZW98 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU1116-1GB0-ZW98 — Protection & Trip
ParameterValue
Overload current setting range4.5 ... 6.3 A
Trip classCLASS 10
3RU1116-1GB0-ZW98 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)6.6 W
Per pole2.2 W
3RU1116-1GB0-ZW98 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU1116-1GB0-ZW98 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU1116-1GB0-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance8g / 10 ms
3RU1116-1GB0-ZW98 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth78 mm
3RU1116-1GB0-ZW98 — Specifications
ParameterValue
Type Of ProtectionDMT 98 ATEX G 001

Product details

Trip class is CLASS 10, which means it will trip within 10 seconds at 7.2× the set current — the standard choice for standard induction motors that don't need the ultra-fast trip of Class 5 or the longer ramp allowance of Class 20. For most conveyor, pump, and fan drives, this is the right call. The control circuit draws 1 A at 24 V, 3 A at 120 V, and 2 A at 230 V — so it's compatible with common control voltages across North American and European panels.

This relay mounts directly onto a SIRIUS contactor — no DIN rail bracket needed, no extra hardware. Clearance requirements are minimal: 0 mm upwards, forwards, backwards, and downwards, with only 6 mm needed at the side. That means you can pack relays side-by-side without worrying about heat buildup from the 2.2 W per pole power loss — just keep the side gap. The main circuit accepts solid conductors: 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²), plus AWG equivalents. Auxiliary contacts take 2x (20...16) and 2x (18...14) AWG. Finely stranded with core-end processing uses the same ranges.

Relative humidity up to 100 % is allowed, so condensation inside a non-heated enclosure won't necessarily cause issues. Shock resistance is rated at 8g for 10 ms — typical for industrial machinery vibration. It carries ATEX approval (DMT 98 ATEX G 001), so it's suitable for use in potentially explosive atmospheres when paired with the correct contactor and upstream protection.

Frequently asked questions

What is the trip class and what does it mean for motor protection?

Trip class is CLASS 10, meaning the relay will trip within 10 seconds at 7.2× the set current. This is the standard choice for general-purpose induction motors — pumps, fans, conveyors — where the starting current is moderate and you don't need the faster Class 5 or the longer ramp of Class 20.

What wire sizes does the 3RU1116-1GB0-ZW98 accept?

Main circuit screw terminals accept solid conductors: 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²), plus AWG equivalents 2x (20...16), 2x (18...14), and 2x 12. Auxiliary contacts accept 2x (20...16) and 2x (18...14) AWG. Finely stranded with core-end processing uses the same ranges.

Does this relay have ATEX approval?

Yes, it carries ATEX approval DMT 98 ATEX G 001, making it suitable for use in potentially explosive atmospheres when properly integrated with the contactor and upstream protection.

What is the mounting clearance required?

Clearance is 0 mm upwards, forwards, backwards, and downwards. Only 6 mm is needed at the side. It mounts directly onto a SIRIUS contactor (contactor mounting) with a vertical mounting surface and ±135° rotation, ±45° tilt.

MPN
3RU1116-1GB0-ZW98