Skip to main content
Siemens 3RU1136-4DB0-ZW96 — Overload Relays

Siemens 3RU1136-4DB0-ZW96 SIRIUS Thermal Overload Relay, CLA

MPN3RU1136-4DB0-ZW96

Siemens SIRIUS thermal overload relay, Size S2, CLASS 10, screw-type terminals, IP20 front, ATEX, 118 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU1136-4DB0-ZW96 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RU1136-4DB0-ZW96 — Protection & Trip
ParameterValue
Overload current setting range18 ... 25 A
Trip classCLASS 10
3RU1136-4DB0-ZW96 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)10.5 W
Per pole3.5 W
3RU1136-4DB0-ZW96 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU1136-4DB0-ZW96 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 3), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU1136-4DB0-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance8g / 10 ms
3RU1136-4DB0-ZW96 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth118 mm
3RU1136-4DB0-ZW96 — Specifications
ParameterValue
Type Of ProtectionDMT 98 ATEX G 001

Product details

The Siemens 3RU1136-4DB0-ZW96 is a SIRIUS thermal overload relay in the Size S2 frame, designed to protect motors against overcurrent by tracking the thermal load and tripping a contactor when the motor draws excessive current over time. The relay mounts directly onto a contactor (contactor mounting) and accepts screw-type terminals for both the main power circuit and the auxiliary/control circuit, which is the conventional wiring method in most industrial control panels.

The main circuit terminals accept solid conductors from 2x (0.5... 1.5 mm²) up to 2x (0.75... 2.5 mm²), and stranded conductors from 2x (0.75... 25 mm²) up to 0.75... 35 mm² — that range covers most motor feeder cables from fractional-horsepower up to about 15 kW at 400 V, so you can land the motor leads without adapters. The auxiliary contacts are rated for switching at various control voltages: 1 A at 24 V, 3 A at 120 V, 2 A at 230 V, and 1 A at 400 V — these are the signal contacts that tell the PLC or starter circuit whether the relay has tripped, and the ratings confirm they handle standard 24 VDC and 120/230 VAC control circuits without derating. The front face carries an IP20 rating, meaning finger-safe against accidental contact but not sealed against dust or moisture — standard for inside a panel where the enclosure provides the environmental seal.

This relay mounts onto a contactor (contactor mounting) and fits the SIRIUS S2 platform, so it mates directly with the corresponding S2 contactor without additional brackets or wiring adapters — the power connections line up, and the auxiliary contacts snap into the control circuit. Clearance requirements are tight: 0 mm upwards, forwards, backwards, and downwards, with only 6 mm needed at the side — meaning it can be packed tightly against adjacent components on a DIN rail or panel, saving space in dense control cabinets.

It withstands 100 % relative humidity during operation, so condensation inside a non-sealed panel won't cause false trips — important for washdown areas or outdoor cabinets. The relay carries ATEX protection type DMT 98 ATEX G 001, meaning it is certified for use in potentially explosive gas atmospheres — this is a key spec for chemical, oil & gas, or grain-handling applications where a motor overload could ignite a surrounding atmosphere. Surge voltage resistance is rated at 6 kV, which aligns with IEC 60947-1 overvoltage category III for fixed installations — it will survive switching transients from contactors and drives without failing. Shock resistance is 8g for 10 ms, enough to handle vibration from nearby motors or conveyor systems without the relay's bimetal strip falsely tripping.

Frequently asked questions

What is the closest functional second-source to 3RU1136-4DB0-ZW96?

The closest functional peer is the 3RT1036-1AB00, which is the corresponding SIRIUS contactor that this relay mounts onto. They share the S2 frame size and the same mounting footprint, so if your panel was designed around the 3RT1036-1AB00 contactor, the 3RU1136-4DB0-ZW96 relay will drop in without rewiring.

What is the depth of 3RU1136-4DB0-ZW96?

The depth is 118 mm, which is the dimension from the mounting surface to the front of the relay — important for enclosure depth clearance.

What solid conductor sizes does the main circuit accept?

The main circuit screw terminals accept solid conductors from 2x (0.5... 1.5 mm²) up to 2x (0.75... 2.5 mm²). For stranded conductors, the range is 2x (0.75... 25 mm²) up to 0.75... 35 mm².

Will 3RU1136-4DB0-ZW96 drop into a panel specified around 3RT1036-1AB00?

Yes, because both parts are SIRIUS S2 size and the relay mounts directly onto the contactor. The power terminals line up, and the auxiliary contacts connect to the control circuit without adapters.

What compliance documentation does this relay carry?

It carries ATEX certification (DMT 98 ATEX G 001) for explosive gas atmospheres, IP20 front protection, and 6 kV surge voltage resistance. The substance prohibitance date of 07/01/2006 indicates RoHS compliance from that date.

MPN
3RU1136-4DB0-ZW96