Skip to main content
Siemens 3RU1136-4EB0-ZX95 — Overload Relays

Siemens 3RU1136-4EB0-ZX95 SIRIUS Thermal Overload Relay, CLA

MPN3RU1136-4EB0-ZX95

Siemens SIRIUS thermal overload relay, size S2, CLASS 10, screw terminals, ATEX, IP20 front, 3RU1136-4EB0-ZX95.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU1136-4EB0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RU1136-4EB0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range22 ... 32 A
Trip classCLASS 10
3RU1136-4EB0-ZX95 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)13.8 W
Per pole4.6 W
3RU1136-4EB0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU1136-4EB0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 3), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU1136-4EB0-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance8g / 10 ms
3RU1136-4EB0-ZX95 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth118 mm
3RU1136-4EB0-ZX95 — Specifications
ParameterValue
Type Of ProtectionDMT 98 ATEX G 001

Product details

SIRIUS thermal overload relay, CLASS 10, ATEX rated

It protects motors against overload and phase failure, with ATEX certification (DMT 98 ATEX G 001) for use in potentially explosive atmospheres.

Trip class and motor protection

For higher-inertia loads (flywheels, crushers) you'd step to CLASS 20 or 30; for submersible or hermetically sealed motors, CLASS 10 is typical. The relay's auxiliary contacts are rated across multiple control voltages: 3 A at 120 V AC, 2 A at 230 V AC, 1 A at 400 V AC, and 1 A at 24 V DC. That covers most PLC input and contactor coil circuits found in a standard panel.

The relay mounts directly onto the contactor — no DIN rail required. Clearances around the unit: 0 mm upwards, forwards, backwards, and downwards; only 6 mm needed at the sides. That means it can be packed tight against adjacent devices in a multi-contactor motor starter group, saving rail space. This accommodates panel layouts where the contactor bank is rotated or angled for cable entry.

Main circuit terminals accept stranded wire from 0.75 to 35 mm² (or 2× 0.75 to 25 mm²), and solid wire from 0.5 to 2.5 mm² (2×). AWG equivalents: main 2× 18 to 3, or 1× 18 to 1; aux 2× 20 to 16 or 2× 18 to 14. Screw-type terminals throughout — no spring-cage on this variant.

Frequently asked questions

What is the trip class of this overload relay?

CLASS 10 — it trips within 10 seconds at 7.2× the current setting, suitable for standard motor starting duty.

What ATEX certification does the 3RU1136-4EB0-ZX95 carry?

It carries DMT 98 ATEX G 001 certification, allowing use in potentially explosive gas atmospheres.

What are the clearance requirements around this relay?

Zero clearance needed upwards, forwards, backwards, and downwards; only 6 mm at the sides. It mounts directly on the contactor.

Where can I buy the 3RU1136-4EB0-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RU1136-4EB0-ZX95