Specifications

3RU1146-4LB0-ZW98 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S3
Combinable contactor sizesS3
Reference code (IEC 81346-2)F
3RU1146-4LB0-ZW98 — Protection & Trip
ParameterValue
Overload current setting range70 ... 90 A
Trip classCLASS 10
3RU1146-4LB0-ZW98 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)1 000 V
Rated surge withstand voltage8 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)21 W
Per pole7 W
3RU1146-4LB0-ZW98 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A, quick: 10 A
Switching current at 24 V1 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU1146-4LB0-ZW98 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionwith vertical mounting surface +/-135° rotatable, with vertical mounting surface +/- 45° tiltable to the front and back
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (10 ... 1/0), 1x (10 ... 2/0)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU1146-4LB0-ZW98 — Environmental
ParameterValue
Operating temperature-20 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance8g / 10 ms
3RU1146-4LB0-ZW98 — Mechanical
ParameterValue
Width70 mm
Height120 mm
Depth140 mm
3RU1146-4LB0-ZW98 — Specifications
ParameterValue
Type Of ProtectionDMT 98 ATEX G 001

Product details

SIRIUS thermal overload relay, Size S3, Class 10

Rated for a wide operating temperature range of -20 to +70 °C and shock resistant to 8g / 10 ms, this relay is built for the vibration and thermal cycling common on conveyor drives, pump skids, and compressor panels. ATEX certification (DMT 98 ATEX G 001) is on record, so the relay can be specified for motor circuits in potentially explosive atmospheres (Zone 1 or Zone 2, gas groups) when paired with a suitably rated contactor and upstream protection.

Auxiliary contact ratings and coordination

The auxiliary contact block is rated for switching at multiple control voltages: 1 A at 24 V, 3 A at 120 V, 2 A at 230 V, and 1 A at 400 V. These are the make/break capacities for the signal circuit — useful for PLC inputs, alarm annunciators, or contactor coil control in the same panel.

Mounting and wiring flexibility

Mounting position is flexible: the relay can be rotated ±135° on a vertical mounting surface and tilted ±45° front-to-back, which helps when fitting into tight panel layouts or existing busbar arrangements. Dimensions are 70 mm wide × 120 mm high × 140 mm deep — a standard S3 footprint that matches the SIRIUS contactor range. Main circuit terminals accept screw-type connections for stranded wire: 2× (10 … 50 mm²) or 10 … 70 mm² single, and AWG equivalents 2× (10 … 1/0) or 1× (10 … 2/0). Auxiliary and control circuit terminals take 2× (0.5 … 1.5 mm²) solid or 2× (0.75 … 2.5 mm²) stranded, with AWG 2× (20 … 16) or 2× (18 … 14). This covers the full range of motor power wiring and control cabling in a typical MCC bucket.

Substance prohibitance date of 07/01/2006 aligns with early RoHS compliance; the ATEX certification (DMT 98 ATEX G 001) provides the documentation needed for hazardous-area installations.

Frequently asked questions

What is 3RU1146-4LB0-ZW98's depth?

The depth is 140 mm, part of the S3 Size footprint (70 mm wide × 120 mm high × 140 mm deep).

What wire sizes does 3RU1146-4LB0-ZW98 accept?

Main circuit terminals accept stranded wire 2× (10 … 50 mm²) or 10 … 70 mm² single (AWG 2× 10 … 1/0 or 1× 10 … 2/0). Auxiliary terminals accept solid 2× (0.5 … 1.5 mm²) or stranded 2× (0.75 … 2.5 mm²) (AWG 2× 20 … 16 or 2× 18 … 14). All terminals are screw-type.

MPN
3RU1146-4LB0-ZW98