Skip to main content
Siemens 3RU2116-0CB0 — Overload Relays

Siemens 3RU2116-0CB0 SIRIUS Thermal Overload Relay, Class 10

MPN3RU2116-0CB0
Active

Siemens SIRIUS 3RU2116-0CB0 thermal overload relay, size S00, Class 10, 690 V rated, screw-type terminals, 45 x 76 x 70 mm.

$96.24Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-0CB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-0CB0 — Protection & Trip
ParameterValue
Overload current setting range0.18 ... 0.25 A
Trip classCLASS 10
Overload release typethermal
3RU2116-0CB0 — Electrical (main circuit)
ParameterValue
Rated operational current0.25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)4.8 W
Per pole1.6 W
3RU2116-0CB0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-0CB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2116-0CB0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-0CB0 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

The Siemens 3RU2116-0CB0 is a SIRIUS-brand thermal overload relay, size S00, designed for motor protection in control panels.

Mounts directly onto the contactor via the fastening method (contactor mounting), with no separate DIN-rail bracket needed. The screw-type terminals accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded copper. For the main circuit, use an M3 screwdriver with a Pozidriv PZ 2 tip, shaft diameter 5–6 mm. The 45 mm width and 70 mm depth fit standard S00 contactor footprints.

Ratings and ambient conditions

The auxiliary switch is integrated and rated for switching at various voltages: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.75 A at 690 V. Operating temperature range is -40…+70 °C, storage/transport -55…+80 °C. Temperature compensation is active from -40…+60 °C, keeping the trip curve stable across the panel environment. Power dissipation per pole is 1.6 W.

Frequently asked questions

What does the 'Note for message Tripped' mean?

That note indicates the relay provides a signal contact that changes state when the overload trips, so a PLC or indicator can detect the fault condition directly.

What are the key dimensions of this overload relay?

Width 45 mm, height 76 mm, depth 70 mm — it fits the standard S00 contactor footprint.

MPN
3RU2116-0CB0