Skip to main content
Siemens 3RU2116-0CB1 — Overload Relays

Siemens 3RU2116-0CB1 SIRIUS Thermal Overload Relay, CLASS 10

MPN3RU2116-0CB1
Active

Siemens SIRIUS thermal overload relay, 3RU2116-0CB1, CLASS 10, size S00, 690 V rated, 80 x 45 x 89 mm, stand-alone screw terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-0CB1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-0CB1 — Protection & Trip
ParameterValue
Overload current setting range0.18 ... 0.25 A
Trip classCLASS 10
Overload release typethermal
3RU2116-0CB1 — Electrical (main circuit)
ParameterValue
Rated operational current0.25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)4.8 W
Per pole1.6 W
3RU2116-0CB1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-0CB1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2116-0CB1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-0CB1 — Mechanical
ParameterValue
Width45 mm
Height89 mm
Depth80 mm

Product details

Power dissipation per pole is 1.6 W, so in a dense panel with several relays side-by-side, account for thermal buildup — mounting position is any, but free airflow helps keep the compensation curve accurate from -40 to +60 °C.

Lifecycle status for 3RU2116-0CB1 is current production. No end-of-life notice or last-time-buy date.

Mounting is stand-alone installation or direct onto a SIRIUS S00 contactor. Screw terminals for the main circuit accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded. The auxiliary switch is integrated, so no separate module is needed for the trip signal. Dimensions are 89 mm height, 45 mm width, 80 mm depth — fits a standard DIN-rail enclosure with room for the contactor below.

Frequently asked questions

How do I get current pricing and availability for 3RU2116-0CB1?

Submit an RFQ through the storefront. Pricing and stock are confirmed at quote time; the part is sourced to order through independent distribution.

What is 3RU2116-0CB1's listed note (for message 'Tripped') on this component line?

The spec carries a note 'for message Tripped' — this means the relay has an integrated auxiliary contact that changes state when the relay trips, providing a dry-contact signal to a PLC or alarm circuit.

What is 3RU2116-0CB1's listed depth (80 mm) on this component line?

The depth is 80 mm, with a width of 45 mm and height of 89 mm. This is the body size; add clearance for wiring and airflow in the enclosure.

Will 3RU2116-0CB1 drop into a panel that was specified around 3RT6028-1AB00 without rewiring?

No — the 3RT6028-1AB00 is a contactor, not an overload relay. The 3RU2116-0CB1 is the correct overload relay to pair with that contactor, but it is a separate device that mounts directly on the contactor or adjacent on the DIN rail. If the panel was built with only the contactor, you will need to add this relay and wire the motor leads through it.

MPN