Skip to main content
Siemens 3RU2116-0EC0 — Overload Relays

Siemens 3RU2116-0EC0 SIRIUS Overload Relay, Class 10, S00

MPN3RU2116-0EC0
Active

Siemens SIRIUS 3RU2116-0EC0 thermal overload relay, size S00, Class 10 trip class, 690 V rated insulation voltage, spring-loaded terminals, contactor mounting.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-0EC0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-0EC0 — Protection & Trip
ParameterValue
Overload current setting range0.28 ... 0.4 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-0EC0 — Electrical (main circuit)
ParameterValue
Rated operational current0.4 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)4.8 W
Per pole1.6 W

Auxiliary contacts

3RU2116-0EC0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-0EC0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)

Environmental

3RU2116-0EC0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-0EC0 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

The 3RU2116-0EC0: Mounts directly onto the contactor via the fastening method — no separate DIN-rail bracket needed.

Auxiliary contact ratings across control voltages

At 60 V it carries 0.3 A, and at 110/125 V it's 0.22 A. These values define the pilot duty capacity for the PLC input or contactor coil it signals.

Environmental and compliance envelope

Storage and transport limits are -55 to +80 °C. The MTTF under high demand rate is 2,280 years, relevant for safety circuit assessments. RoHS compliance date is October 1, 2009.

Listed as current production — this is an active SIRIUS catalog item.

Frequently asked questions

What does the note 'for message Tripped' mean on the 3RU2116-0EC0?

The note indicates the auxiliary contact position labeled 'Tripped' — it's the normally-open contact that closes when the relay has tripped on overload, providing a signal back to the PLC or indicator. It's not a separate function; it's the standard alarm contact on this relay.

What compliance documentation is available for the 3RU2116-0EC0?

RoHS compliance is dated October 1, 2009. The relay carries a 690 V rated insulation voltage and is designed for 50/60 Hz operation. Standard Siemens SIRIUS documentation (datasheet, CE declaration, UL file) applies — verify specific UL/CSA listing against the latest manufacturer documentation at order time.

MPN
3RU2116-0EC0