Skip to main content
Siemens 3RU2116-0FC0-ZW97 — Overload Relays

Siemens 3RU2116-0FC0-ZW97 SIRIUS Thermal Overload Relay, Cla

MPN3RU2116-0FC0-ZW97
Active

Siemens SIRIUS thermal overload relay, size S00, CLASS 10, 690 V rated value, 50/60 Hz, spring-loaded terminals, contactor mounting, for message Tripped.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-0FC0-ZW97 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-0FC0-ZW97 — Protection & Trip
ParameterValue
Overload current setting range0.35 ... 0.5 A
Trip classCLASS 10
Overload release typethermal
3RU2116-0FC0-ZW97 — Electrical (main circuit)
ParameterValue
Rated operational current0.5 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)4.8 W
Per pole1.6 W
3RU2116-0FC0-ZW97 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-0FC0-ZW97 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)
3RU2116-0FC0-ZW97 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-0FC0-ZW97 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

It is rated for a maximum voltage of 690 V and operates at 50/60 Hz. This variant includes a spring-loaded terminal block for the main current circuit and is intended for direct mounting onto a contactor.

Trip Class and Release Design

The overload release is thermal (bimetal) type, providing an inverse-time characteristic that tracks motor heating. The auxiliary switch is integrated into the relay body.

Switching Capacity by Voltage

The auxiliary contacts are rated for specific switching capacities depending on the control voltage: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.3 A at 60 V, among others. These ratings define the maximum current the auxiliary contacts can safely interrupt at the given voltage — critical for sizing the control circuit load.

Temperature compensation is active from -40 to +60 °C, ensuring the trip curve remains accurate across the working range. The MTTF under high demand is rated at 2,280 years, reflecting the reliability of the electromechanical design.

Mounting and Connection

Mounting is via contactor mounting — it snaps directly onto the matching Siemens contactor, eliminating separate DIN-rail space. The spring-loaded terminals accept 2 × (0.5 to 2.5 mm²) solid or stranded wire. A 3 mm diameter screwdriver is specified for the terminal screws.

Frequently asked questions

What does the note 'for message Tripped' mean on this relay?

The note indicates that this specific variant includes an auxiliary contact configuration that signals a 'Tripped' message, typically used to indicate an overload condition to a PLC or HMI.

What is the depth of the 3RU2116-0FC0-ZW97?

The depth is 70 mm, with a width of 45 mm and height of 87 mm, fitting the S00 frame size.

Will 3RU2116-0FC0-ZW97 drop into a panel specified around 3RU2116-1FC1?

Both are S00 frame size thermal overload relays from the same SIRIUS family, sharing the same mounting footprint and contactor interface. The primary difference is the auxiliary contact configuration and terminal type; the 0FC0-ZW97 uses spring-loaded terminals and includes the 'Tripped' message auxiliary contact. Physical interchangeability is expected, but verify the auxiliary contact wiring requirements for your specific control circuit.

Where can I buy 3RU2116-0FC0-ZW97 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3RU2116-0FC0-ZW97