Siemens 3RU2116-0GB0-ZX95 — Overload Relays

Siemens 3RU2116-0GB0-ZX95 SIRIUS Overload Relay, Class 10

MPN3RU2116-0GB0-ZX95
Active

Siemens SIRIUS 3RU2116-0GB0-ZX95 thermal overload relay, Size S00, Class 10, 690 V rated, screw terminals, auxiliary contact with trip signal, contactor mounting.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-0GB0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-0GB0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range0.45 ... 0.63 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-0GB0-ZX95 — Electrical (main circuit)
ParameterValue
Rated operational current0.63 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)4.8 W
Per pole1.6 W

Auxiliary contacts

3RU2116-0GB0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-0GB0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)

Environmental

3RU2116-0GB0-ZX95 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-0GB0-ZX95 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

What the Class 10 and Size S00 ratings mean for fit

The 3RU2116-0GB0-ZX95: For high-inertia loads like centrifuges or crushers, a Class 20 or 30 relay would be needed to avoid nuisance trips during start-up. It mounts directly onto the matching Siemens contactor (no DIN rail required), saving panel space and reducing wiring — the power connections pass through the contactor, not the relay.

Auxiliary contact signals the trip — what the note means

The note 'for message Tripped' indicates that the integrated auxiliary contact changes state when the relay trips, providing a discrete signal to a PLC input, indicator lamp, or annunciator. This is the 'trip alarm' contact — separate from the contactor coil circuit, so the control system knows the motor has been stopped by an overload, not by a normal stop command. Confirm the control voltage and load type (resistive vs. inductive) against these ratings to ensure reliable switching.

Temperature compensation and environmental range

The relay is temperature-compensated from -40 to +60 °C, meaning the trip curve stays accurate across that ambient range without manual adjustment. This matters for outdoor enclosures, unheated pump houses, or near hot machinery where ambient temperature varies. The relay can be stored in unconditioned warehouses and installed in most industrial environments without derating for temperature alone.

As an active-production Siemens SIRIUS part, the 3RU2116-0GB0-ZX95 is sourced through authorized distribution channels. Pricing and lead time are confirmed at RFQ against the BOM quantity — no minimum order restriction for this standard catalog item.

Frequently asked questions

What does the note 'for message Tripped' mean on this overload relay?

The note indicates the integrated auxiliary contact is wired to signal a trip condition — it changes state when the relay trips, providing a discrete output to a PLC, indicator, or alarm. This is separate from the contactor coil circuit.

MPN
3RU2116-0GB0-ZX95