Skip to main content
Siemens 3RU2116-0HJ0 — Overload Relays

Siemens 3RU2116-0HJ0 SIRIUS Thermal Overload Relay, Class 10

MPN3RU2116-0HJ0

Siemens SIRIUS 3RU2116-0HJ0 thermal overload relay, Size S00, Trip Class 10, 690 V rated, 45 mm wide, contactor-mount, integrated auxiliary switch.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-0HJ0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-0HJ0 — Protection & Trip
ParameterValue
Overload current setting range0.55 ... 0.8 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-0HJ0 — Electrical (main circuit)
ParameterValue
Rated operational current0.8 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitRing cable lug connection
Power loss at rated current (hot)4.8 W
Per pole1.6 W

Auxiliary contacts

3RU2116-0HJ0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-0HJ0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typering terminal lug connection
Removable aux./control terminalNo

Environmental

3RU2116-0HJ0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-0HJ0 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

What the Trip Class and size mean for motor protection

The 3RU2116-0HJ0: That suits standard motor start-ups where the inrush doesn't stretch beyond a few seconds; a Class 20 or 30 would be for high-inertia loads like fans or crushers. Size S00 means it mates with the matching S00 contactor frame — the relay snaps directly onto the contactor without extra DIN-rail space. The 45 mm width and 70 mm depth keep the assembly tight in a crowded enclosure.

Wiring and auxiliary contact ratings

Main circuit termination uses ring cable lugs — you torque the M3 screws on the contactor's main terminals. That's a solid connection for motor feeders, no push-in or spring cage here. The integrated auxiliary switch has a note "for message 'Tripped'" — meaning it signals the relay's tripped state, not the contactor's coil status. That covers most PLC input modules and indicator lamps.

Frequently asked questions

What does the note 'for message Tripped' mean on the 3RU2116-0HJ0?

The integrated auxiliary switch is wired to signal the relay's tripped state — it closes or opens when the overload relay has tripped, not when the contactor is energized. This is a status message for a PLC or indicator, not a control signal for the contactor coil.

MPN
3RU2116-0HJ0