Siemens 3RU2116-0KB0 — Overload Relays

Siemens 3RU2116-0KB0 SIRIUS thermal overload relay, CLASS 10

MPN3RU2116-0KB0
Active

Siemens SIRIUS thermal overload relay, 3RU2116-0KB0, CLASS 10, size S00, rated 690 V, auxiliary contacts rated at multiple voltages.

$94.53Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RU2116-0KB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-0KB0 — Protection & Trip
ParameterValue
Overload current setting range0.9 ... 1.25 A
Trip classCLASS 10
Overload release typethermal
3RU2116-0KB0 — Electrical (main circuit)
ParameterValue
Rated operational current1.25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W
3RU2116-0KB0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-0KB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2116-0KB0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-0KB0 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

The 3RU2116-0KB0: CLASS 10 means the relay trips within 10 seconds at 7.2× the current setting — standard for motor protection where the starting profile is moderate (pumps, fans, compressors). The auxiliary contact ratings are given per voltage because the switching capacity is limited by arc extinction at higher voltages; at 690 V the contact is rated 0.75 A, so if your control circuit runs at that level, verify the load current stays under that limit.

Mounts directly onto the contactor via the fastening method specified — no DIN rail needed. Screw-type terminals on the main circuit accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). The auxiliary switch is integrated, so no separate add-on block required. Dimensions: 45 mm wide, 76 mm high, 70 mm deep — fits standard panel layouts.

Operating temperature range -40 to +70 °C, with temperature compensation active from -40 to +60 °C — meaning the trip curve stays accurate across that span. The relay carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance. MTTF with high demand rate is 2,280 years — a reliability figure for safety-related applications.

Frequently asked questions

What is the note 'for message Tripped' on this component?

The note indicates that the relay's auxiliary contact position is labeled to signal a 'Tripped' condition — typically a normally-closed contact that opens when the relay trips.

MPN