Siemens 3RU2116-0KC0-ZW97 — Overload Relays

Siemens 3RU2116-0KC0-ZW97 SIRIUS Thermal Overload Relay, Cla

MPN3RU2116-0KC0-ZW97
Active

Siemens SIRIUS thermal overload relay, size S00, CLASS 10, 690 V rated, spring-loaded terminals, auxiliary contact ratings 2 A at 24 V / 3 A at 120 V / 2 A at 230 V, order code 3RU2116-0KC0-ZW97.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-0KC0-ZW97 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-0KC0-ZW97 — Protection & Trip
ParameterValue
Overload current setting range0.9 ... 1.25 A
Trip classCLASS 10
Overload release typethermal
3RU2116-0KC0-ZW97 — Electrical (main circuit)
ParameterValue
Rated operational current1.25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W
3RU2116-0KC0-ZW97 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-0KC0-ZW97 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)
3RU2116-0KC0-ZW97 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-0KC0-ZW97 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

The Siemens 3RU2116-0KC0-ZW97 is a SIRIUS thermal overload relay in size S00, CLASS 10 trip, 690 V rated, 50 to 60 Hz, contactor mounting. The auxiliary contact set is rated across multiple voltages: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.3 A at 60 V, among others. These ratings cover both control-circuit and signal-feedback wiring — the 24 V and 120 V figures matter most for PLC inputs and relay coils in a typical panel.

The main current circuit uses spring-loaded terminals, accepting 2 × (0.5 to 2.5 mm²) solid or stranded conductors. The screwdriver shaft diameter is 3 mm with a 3.0 × 0.5 mm tip size for the auxiliary terminal screws.

Physical footprint and environment

Integrated auxiliary switch.

Frequently asked questions

What is the closest functional second-source to 3RU2116-0KC0-ZW97?

The 3RU2116-1FC1 is a peer in the same SIRIUS size S00 family. Both are CLASS 10 thermal overload relays with the same mounting footprint and terminal style. The difference is in the auxiliary contact configuration and possibly the current setting range — verify the specific rating plate before substituting, but the mechanical fit is identical.

MPN
3RU2116-0KC0-ZW97