Siemens 3RU2116-1BB0-ZW97 — Overload Relays

Siemens 3RU2116-1BB0-ZW97 SIRIUS Thermal Overload Relay, Siz

MPN3RU2116-1BB0-ZW97
Active

Siemens SIRIUS 3RU2116-1BB0-ZW97 thermal overload relay, Size S00, Class 10 trip, 690 V rated, 2 A at 24 V, 3 A at 120 V, screw terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-1BB0-ZW97 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-1BB0-ZW97 — Protection & Trip
ParameterValue
Overload current setting range1.4 ... 2 A
Trip classCLASS 10
Overload release typethermal
3RU2116-1BB0-ZW97 — Electrical (main circuit)
ParameterValue
Rated operational current2 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W
3RU2116-1BB0-ZW97 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-1BB0-ZW97 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2116-1BB0-ZW97 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-1BB0-ZW97 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

The Siemens 3RU2116-1BB0-ZW97 is a SIRIUS thermal overload relay in the Size S00 frame, designed for direct contactor mounting on the SIRIUS 3RT2 series. The relay uses a thermal bimetallic release, so it tracks the motor's true thermal state, not just a fixed curve. It clips directly onto the contactor — no separate DIN-rail footprint needed — and the auxiliary switch is integrated into the housing, saving panel space.

At 24 V it switches 2 A; at 120 V it handles 3 A; at 230 V it's 2 A; and at 400 V it's 1 A. These are the auxiliary contact ratings for the trip-indicating circuit — the note "for message 'Tripped'" means this variant includes a remote signal contact that changes state when the relay trips, so a PLC or HMI can log the fault. Temperature compensation is active from -40 °C to +60 °C, so the trip curve stays accurate across most industrial environments.

The relay carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance per EU Directive 2002/95/EC. It is part of the SIRIUS family, which typically holds UL, CSA, and CE certifications — verify the specific approvals on the nameplate for your jurisdiction, but the platform is globally accepted.

Frequently asked questions

What does the note "for message 'Tripped'" mean?

It means this variant includes an integrated auxiliary switch that provides a remote signal when the relay trips, so a controller can log the fault. The switch ratings are 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, and 1 A at 400 V.

What is the closest functional second-source to the 3RU2116-1BB0-ZW97?

The 3RV1011-1HA10 is a motor starter protector (circuit breaker + overload) in the same SIRIUS S00 frame, but it is a different device class — it combines short-circuit and overload protection in one unit, whereas the 3RU2116 is a thermal overload relay only, designed to mount on a contactor. They are not direct drop-in replacements without rewiring the motor branch circuit.

What is the depth of the 3RU2116-1BB0-ZW97?

The depth is 70 mm, width 45 mm, height 76 mm. This is the Size S00 frame, which mounts directly on SIRIUS 3RT2 contactors without extra DIN-rail space.

Will the 3RU2116-1BB0-ZW97 drop into a panel specified around the 3RV1011-1HA10?

No, not without rewiring. The 3RV1011-1HA10 is a motor starter protector that combines a circuit breaker and overload relay in one unit, wired directly to the motor. The 3RU2116 is a thermal overload relay that mounts on a contactor and requires a separate upstream short-circuit protection device. The footprint is similar (both S00 frame), but the circuit topology is different.

What compliance documentation is available for the 3RU2116-1BB0-ZW97?

The relay has a substance prohibitance date of 10/01/2009, indicating RoHS compliance. As a SIRIUS product, it typically carries UL, CSA, and CE certifications — check the specific nameplate for your jurisdiction's marks.

MPN
3RU2116-1BB0-ZW97