Siemens 3RU2116-1CB0-ZW96 — Overload Relays

Siemens 3RU2116-1CB0-ZW96 SIRIUS Overload Relay, CLASS 10

MPN3RU2116-1CB0-ZW96
Active

Siemens SIRIUS 3RU2116-1CB0-ZW96 thermal overload relay, CLASS 10, S00 size, 690 V rated, screw-type terminals, 45 x 76 x 70 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-1CB0-ZW96 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-1CB0-ZW96 — Protection & Trip
ParameterValue
Overload current setting range1.8 ... 2.5 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-1CB0-ZW96 — Electrical (main circuit)
ParameterValue
Rated operational current2.5 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W

Auxiliary contacts

3RU2116-1CB0-ZW96 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-1CB0-ZW96 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)

Environmental

3RU2116-1CB0-ZW96 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-1CB0-ZW96 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

S00 frame, CLASS 10 trip — what that means for motor protection

The 3RU2116-1CB0-ZW96: This is a Siemens SIRIUS thermal overload relay in the S00 frame size — the smallest in the SIRIUS modular system, sized for contactors up to about 7 kW at 400 V. The "ZW96" suffix on the order code signals a factory-fitted auxiliary contact block configured to signal a "Tripped" message — the relay carries an integrated auxiliary switch that changes state when the bimetal strip has tripped, so a PLC or annunciator sees the fault without extra wiring.

Mounting and panel fit — direct contactor mount, any orientation

The relay fastens directly onto the matching SIRIUS contactor — no DIN rail bracket needed, no separate footprint. Mounting position is unrestricted — the thermal bimetal is temperature-compensated from -40 °C to +60 °C, so the relay can be mounted horizontally, vertically, or flat without recalibrating the trip curve. The dimensions are 45 mm wide, 76 mm high, 70 mm deep — the depth is the overhang past the contactor face, so the total depth of the contactor-plus-relay stack is about 70 mm from the mounting surface.

Auxiliary contact ratings and the tripped-signal variant

The 0.3 A at 60 V and 0.11 A at 220 V figures fill the intermediate voltages common in legacy control circuits. The "for message Tripped" note means the auxiliary contact is wired as a normally-open that closes on trip — the PLC input sees a dry contact close when the bimetal releases, not a break. This is the standard configuration for a remote fault indication loop.

Sourcing and compliance — active production, RoHS dated

RoHS compliance is documented with a substance prohibitance date of 10/01/2009 — the relay meets the EU RoHS directive effective from that date.

MPN
3RU2116-1CB0-ZW96