Siemens 3RU2116-1CC0-ZW97 — Overload Relays

Siemens 3RU2116-1CC0-ZW97 SIRIUS Thermal Overload Relay, CLA

MPN3RU2116-1CC0-ZW97
Active

Siemens SIRIUS thermal overload relay, Size S00, CLASS 10, contactor mounting, spring-loaded terminals, 690 V rated, 50-60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2116-1CC0-ZW97 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-1CC0-ZW97 — Protection & Trip
ParameterValue
Overload current setting range1.8 ... 2.5 A
Trip classCLASS 10
Overload release typethermal
3RU2116-1CC0-ZW97 — Electrical (main circuit)
ParameterValue
Rated operational current2.5 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W
3RU2116-1CC0-ZW97 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-1CC0-ZW97 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)
3RU2116-1CC0-ZW97 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-1CC0-ZW97 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

Rated for a main circuit voltage up to 690 V at 50-60 Hz, this relay carries a note for message "Tripped" — a local visual and electrical indication that the overload has operated, which is wired into the control circuit to signal a fault condition to the PLC or HMI. Switching capacity varies by control voltage: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, and 1 A at 400 V. These are the ratings for the integrated auxiliary switch contacts, not the main power path — they drive the trip signal back to the controller.

Mounts directly onto a contactor via the contactor mounting fastening method — no DIN rail required, saving panel space. The Size S00 footprint (45 mm wide, 87 mm tall, 70 mm deep) fits the standard SIRIUS S00 contactor range. Any mounting position is permitted, and spring-loaded terminals accept 2× (0.5 to 2.5 mm²) solid or stranded wire. The integrated auxiliary switch design eliminates the need for a separate add-on block for the trip signal, reducing component count and wiring. Temperature compensation is active from -40 to +60 °C, keeping the trip curve stable across the operating range.

Compliance documentation includes RoHS substance prohibitance dated 10/01/2009. The relay carries an MTTF of 2,280 years under high-demand rate — a reliability figure that reflects the thermal-mechanical design's inherent robustness, not a service-life guarantee.

Frequently asked questions

What does the note 'for message Tripped' mean?

The note indicates the relay provides a local and electrical signal when the overload has tripped, which can be wired to a PLC or HMI to indicate a fault condition.

What is the closest functional second-source to 3RU2116-1CC0-ZW97?

The 3RU2116-1FC1 is a peer in the same SIRIUS S00 family with the same CLASS 10 trip class and contactor mounting. The -1CC0-ZW97 variant carries the 'for message Tripped' note, while the -1FC1 may differ in auxiliary contact configuration. Verify the specific auxiliary contact arrangement before substituting.

Where can I buy 3RU2116-1CC0-ZW97 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RU2116-1CC0-ZW97 drop into a panel specified for 3RU2116-1FC1?

Both are Size S00 with contactor mounting and CLASS 10 trip, so the mechanical fit and mounting are identical. The difference is in the auxiliary switch note — the -1CC0-ZW97 is specifically configured for a 'Tripped' message output. If the panel wiring expects that signal, it drops in without rewiring.