Skip to main content
Siemens 3RU2116-1DC0-ZX95 — Overload Relays

Siemens 3RU2116-1DC0-ZX95 SIRIUS Overload Relay, CLASS 10

MPN3RU2116-1DC0-ZX95
Active

Siemens SIRIUS 3RU2116-1DC0-ZX95 thermal overload relay, CLASS 10, size S00, 690 V rated, spring-loaded terminals, integrated auxiliary switch with trip indication.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-1DC0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-1DC0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range2.2 ... 3.2 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-1DC0-ZX95 — Electrical (main circuit)
ParameterValue
Rated operational current3.2 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)5.7 W
Per pole1.9 W

Auxiliary contacts

3RU2116-1DC0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-1DC0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)

Environmental

3RU2116-1DC0-ZX95 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-1DC0-ZX95 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

Trip indication and motor protection logic

The 3RU2116-1DC0-ZX95 carries a note for message "Tripped" — the integrated auxiliary switch signals the PLC or HMI directly when the relay operates, so the control system knows the motor dropped off without polling the overload via the power circuit.

Auxiliary contact ratings for signal compatibility

At 60 V the contact is rated 0.3 A, and at 110 V or 125 V it carries 0.22 A — useful for legacy 110 VDC control circuits or specialised 60 V signalling.

S00 footprint and wiring

Size S00 with 70 mm depth, 45 mm width, and 87 mm height — this mounts directly onto the matching S00 contactor (e.g. 3RT201) without extra brackets, saving DIN-rail space.

The relay carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance from that date onward.

Frequently asked questions

What does the note 'for message Tripped' mean on the 3RU2116-1DC0-ZX95?

It means the integrated auxiliary switch provides a dedicated signal output that changes state when the overload relay trips, so the control system receives a direct 'tripped' indication without needing to sense motor current separately.

What is the closest alternative to the 3RU2116-1DC0-ZX95 in the SIRIUS family?

The standard 3RU2116-1DC0 (without the -ZX95 suffix) is the base variant. The -ZX95 suffix typically indicates a special version or custom configuration — confirm the specific BOM requirement before substituting.

MPN