Specifications

3RU2116-1JB1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RU2116-1JB1 — Protection & Trip
ParameterValue
Overload current setting range7 ... 10 A
Trip classCLASS 10
Overload release typethermal
3RU2116-1JB1 — Electrical (main circuit)
ParameterValue
Rated operational current10 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)6.6 W
Per pole2.2 W
3RU2116-1JB1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2116-1JB1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2116-1JB1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2116-1JB1 — Mechanical
ParameterValue
Width45 mm
Height89 mm
Depth80 mm

Product details

The Siemens 3RU2116-1JB1 is a SIRIUS thermal overload relay, size S00, Trip Class 10, rated for main circuit voltages up to 690 V. It directly mounts to a contactor or stands alone — the fastening method is stand-alone installation, so you can fix it where it sits without a DIN-rail adapter if that's what the panel calls for.

Auxiliary contact ratings — what they mean on site

The integrated auxiliary switch (design of the auxiliary switch: integrated) carries a range of voltage-dependent currents: 2 A at 24 V, 0.3 A at 60 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.75 A at 690 V. That means the same set of contacts handles both a 24 V PLC input and a 400 V contactor coil, as long as you respect the current at that voltage — no separate aux block needed.

Trip Class 10 — what it means for motor protection

Class 10 trip means the relay will open within 10 seconds at a locked-rotor current of 600 % of the full-load setting. For a motor that starts fast (conveyors, pumps, fans with light starts), that's enough time to get up to speed without nuisance tripping. If you're on a high-inertia load like a centrifuge or crusher that needs a longer start, you'd want Class 20 or 30 — but for most standard induction motors, Class 10 is the right call.

At 45 mm wide, 89 mm tall, and 80 mm deep, the S00 footprint is compact — it fits in the same slot as the matching S00 contactor. Terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded, screw-type with a Pozidriv PZ 2 tip and 5–6 mm shaft diameter.

Frequently asked questions

What is the note 'for message Tripped' on this relay?

The note 'for message Tripped' indicates that the auxiliary contact position signals a tripped state — it's a status output, not a control contact.

Where can I buy 3RU2116-1JB1 and get current pricing?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
3RU2116-1JB1