Siemens 3RU2116-1JC0-ZW97 — Overload Relays

Siemens 3RU2116-1JC0-ZW97 SIRIUS Overload Relay, CLASS 10

MPN3RU2116-1JC0-ZW97
Active

Siemens SIRIUS 3RU2116-1JC0-ZW97 thermal overload relay, Size S00, CLASS 10, 45 mm width, spring-loaded terminals, integrated auxiliary switch for message 'Tripped', contactor mounting.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-1JC0-ZW97 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-1JC0-ZW97 — Protection & Trip
ParameterValue
Overload current setting range7 ... 10 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-1JC0-ZW97 — Electrical (main circuit)
ParameterValue
Rated operational current10 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)6.6 W
Per pole2.2 W

Auxiliary contacts

3RU2116-1JC0-ZW97 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-1JC0-ZW97 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)

Environmental

3RU2116-1JC0-ZW97 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-1JC0-ZW97 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

What the 'Tripped' message variant buys you

The 3RU2116-1JC0-ZW97 carries the note 'for message Tripped' — meaning it ships with an integrated auxiliary switch that closes a separate signal circuit when the overload relay trips. That gives the panel builder a dry-contact status back to a PLC input, annunciator lamp, or HMI without bolting on an extra auxiliary block. For a maintenance tech walking a line, that signal pinpoints which motor dropped off without opening the cabinet door.

Trip class and motor protection timing

That's the standard for general-purpose induction motors — the inrush during start clears before the thermal element accumulates enough heat to trip, but a locked-rotor condition gets caught fast enough to keep the winding insulation from cooking. The thermal overload release is temperature-compensated from -40 to +60 °C, so the trip curve doesn't drift when the panel ambient climbs on a summer afternoon or drops during a cold startup. That matters for a pump house or outdoor MCC where the internal cabinet temperature swings more than a climate-controlled server room.

Panel fit and wiring — Size S00 with spring terminals

Size S00 is the smallest SIRIUS overload relay footprint: 45 mm wide, 87 mm tall, 70 mm deep. It mounts directly onto the matching SIRIUS contactor (not on DIN rail) — the power connections pass through the contactor's own terminals, saving one wiring layer and a few inches of panel width. For a panel OEM packing multiple motor starters into a compact enclosure, that 45 mm per starter adds up fast. The auxiliary switch uses the same clamp style, so the whole relay wires with one tool.

Frequently asked questions

What does the 'for message Tripped' note on the 3RU2116-1JC0-ZW97 mean?

It means this variant includes an integrated auxiliary switch that closes a separate signal circuit when the overload relay trips. That gives you a dry-contact status output — typically wired to a PLC digital input or an annunciator — without needing a separate auxiliary contact block. The switch is built into the relay body.

MPN
3RU2116-1JC0-ZW97