Siemens 3RU2116-4AB0-ZX95 — Overload Relays

Siemens 3RU2116-4AB0-ZX95 Thermal Overload Relay, CLASS 10

MPN3RU2116-4AB0-ZX95
Active

Siemens SIRIUS 3RU2116-4AB0-ZX95 thermal overload relay, CLASS 10, Size S00, 690 V rated, screw-type terminals, contactor mounting.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-4AB0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-4AB0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range11 ... 16 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-4AB0-ZX95 — Electrical (main circuit)
ParameterValue
Rated operational current16 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)8.1 W
Per pole2.7 W

Auxiliary contacts

3RU2116-4AB0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-4AB0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)

Environmental

3RU2116-4AB0-ZX95 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-4AB0-ZX95 — Mechanical
ParameterValue
Width45 mm
Height76 mm
Depth70 mm

Product details

Trip class and what it means on the line

The 3RU2116-4AB0-ZX95: If you're guarding a high-inertia load that needs a longer acceleration ramp, CLASS 10 may trip before the motor is up to speed; you'd step up to CLASS 20 or CLASS 30.

Size S00 — panel fit and mounting

It mounts directly onto the contactor via the fastening method listed as 'contactor mounting', so no separate DIN-rail clip or bracket is needed.

Auxiliary contact note — 'Tripped' message

The relay carries a note: 'for message Tripped'. That means the integrated auxiliary switch is wired to signal a trip condition — not just a standard NO/NC status, but a dedicated 'tripped' indication. On the line, that lets the PLC or HMI display a specific fault message rather than a generic 'overload' alarm, which speeds up troubleshooting.

Frequently asked questions

What is the 3RU2116-4AB0-ZX95's trip class and what does it mean?

That suits standard motor starts but may be too fast for high-inertia loads.

MPN
3RU2116-4AB0-ZX95