Siemens SIRIUS 3RU2116-4AC0-ZX95 thermal overload relay, CLASS 10, size S00, 690 V rated insulation voltage, 7.5 kW at 400 V, spring-loaded terminals, auxiliary switch integrated.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2116-4AC0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F

Protection & Trip

3RU2116-4AC0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range11 ... 16 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2116-4AC0-ZX95 — Electrical (main circuit)
ParameterValue
Rated operational current16 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)8.1 W
Per pole2.7 W

Auxiliary contacts

3RU2116-4AC0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2116-4AC0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts1x (20 ... 12)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)

Environmental

3RU2116-4AC0-ZX95 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2116-4AC0-ZX95 — Mechanical
ParameterValue
Width45 mm
Height87 mm
Depth70 mm

Product details

Motor protection trip class and what it means on the line

The 3RU2116-4AC0-ZX95 is a SIRIUS thermal overload relay, size S00, designed to protect AC motors against overload and phase failure by monitoring the motor current and tripping the contactor via its integrated auxiliary switch.

At 110 V and 125 V the rating drops to 0.22 A, and at 220 V to 0.11 A — if your control circuit runs at one of these voltages, verify the auxiliary contact can handle the connected load without derating. The note "for message 'Tripped'" on the spec line indicates this variant includes a remote trip-indication contact — it signals the PLC or HMI that the relay has operated, not just the local flag.

Panel fit, wiring, and environmental limits

Fastening method is contactor mounting — it clips directly onto the matching SIRIUS contactor (S00 frame), no DIN rail bracket needed, saving panel width. Mounting position is any orientation, so it fits in tight enclosures without derating for sideways or inverted installation. Dimensions are 45 mm wide, 87 mm high, 70 mm deep — the width matches the S00 contactor footprint, keeping the motor starter assembly compact. Power dissipation per pole is 2.7 W at rated current — three poles dissipate about 8.1 W total, which must be considered in the enclosure thermal budget.

MTTF with high demand rate is 2,280 years — a reliability figure that supports use in safety-related applications where the relay is exercised frequently. Substance prohibitance date is 10/01/2009, indicating RoHS compliance per the EU directive effective from that date.

Frequently asked questions

What does the note 'for message Tripped' mean on this overload relay?

It means the integrated auxiliary switch is wired to send a remote trip indication signal — typically a normally-closed contact that opens when the relay trips, feeding a PLC input or a status lamp.

What is the depth of 3RU2116-4AC0-ZX95 for panel clearance?

Depth is 70 mm — this is the dimension behind the panel face when mounted on the contactor, not including the manual reset button protrusion.

What compliance documentation does Siemens provide for 3RU2116-4AC0-ZX95?

The substance prohibitance date of 10/01/2009 confirms RoHS compliance. Additional documentation (UL, CSA, CE, UKCA, EAC) is typically available from the manufacturer's support portal for this SIRIUS series.

MPN
3RU2116-4AC0-ZX95