Skip to main content
Siemens 3RU2126-4PB1 — Overload Relays

Siemens 3RU2126-4PB1 SIRIUS Overload Relay, CLASS 10, S0

MPN3RU2126-4PB1
Active

Siemens SIRIUS 3RU2126-4PB1 thermal overload relay, CLASS 10, S0 frame size, 95 mm depth, screw-type terminals, auxiliary switch integrated.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2126-4PB1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S0
Combinable contactor sizesS0
Reference code (IEC 81346-2)F

Protection & Trip

3RU2126-4PB1 — Protection & Trip
ParameterValue
Overload current setting range30 ... 36 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2126-4PB1 — Electrical (main circuit)
ParameterValue
Rated operational current36 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)9.6 W
Per pole3.2 W

Auxiliary contacts

3RU2126-4PB1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2126-4PB1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (16 ... 12), 2x (14 ... 8)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)

Environmental

3RU2126-4PB1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2126-4PB1 — Mechanical
ParameterValue
Width45 mm
Height97 mm
Depth95 mm

Product details

SIRIUS 3RU2126-4PB1 — what this overload relay does

The Siemens 3RU2126-4PB1 is a SIRIUS thermal overload relay designed to protect motors against overcurrent and phase-loss conditions. That's the standard for standard-duty motor starting — it lets the motor accelerate under load without nuisance tripping but still clears a locked-rotor condition fast enough to protect the winding insulation.

At 400 V rated voltage, this relay handles 18.5 kW motor load; at 500 V it's rated 22 kW, and at 690 V it goes to 30 kW. At 60 V it's only 0.3 A, so watch that if you're running a 60 VDC control bus. Power dissipation per pole is 3.2 W. In a densely packed panel with multiple relays side by side, that adds up — budget the thermal rise in the enclosure, especially if the ambient hits the upper end of the -40 to +70 °C operating range. Temperature compensation is active from -40 to +60 °C, meaning the trip characteristic stays accurate across that band without manual adjustment. Outside that range the thermal model drifts — but the storage and transport limits are wider at -55 to +80 °C.

The screw terminal requires a Pozidriv PZ 2 tip with a 5–6 mm shaft diameter — standard electrician's screwdriver, nothing special.

No official successor has been published; the 3RU2 series is the active SIRIUS overload relay line and the 3RU2126-4PB1 remains the correct order code for S0-frame CLASS 10 applications at these power ratings.

Frequently asked questions

How can I order the 3RU2126-4PB1 and check availability?

This part is quoted to order against your BOM quantity.

What does the 'for message Tripped' note mean on this relay?

The note indicates that the auxiliary switch integrated into the relay provides a signal output when the overload relay has tripped. This is the 'tripped' message contact that feeds back to the PLC or indicator lamp.

What compliance documentation does Siemens provide for the 3RU2126-4PB1?

The relay carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance. It is designed to meet IEC/EN 60947-4-1 standards for motor protection devices. Full compliance declarations are available from Siemens.

MPN