Skip to main content
Siemens 3RU2136-1HB0 — Overload Relays

Siemens 3RU2136-1HB0 SIRIUS Thermal Overload Relay, Class 10

MPN3RU2136-1HB0
Active

Siemens SIRIUS 3RU2136-1HB0 thermal overload relay, Size S2, Trip Class 10, rated 690 V, contactor mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2136-1HB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RU2136-1HB0 — Protection & Trip
ParameterValue
Overload current setting range5.5 ... 8 A
Trip classCLASS 10
Overload release typethermal
3RU2136-1HB0 — Electrical (main circuit)
ParameterValue
Rated operational current8 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)7.5 W
Per pole2.5 W
3RU2136-1HB0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2136-1HB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 2), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2136-1HB0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2136-1HB0 — Mechanical
ParameterValue
Width55 mm
Height90 mm
Depth105 mm

Product details

SIRIUS 3RU2136-1HB0 — Thermal Overload Relay, Size S2, Class 10

The Siemens 3RU2136-1HB0 is a SIRIUS thermal overload relay, Size S2, designed for motor protection with Trip Class 10 tripping characteristic. It mounts directly onto a contactor and provides bimetallic thermal overload protection for three-phase motors up to 690 V rated voltage. The integrated auxiliary switch provides status signalling: the 'Tripped' message contact changes state when the relay has operated, giving the PLC or HMI a direct fault indication without needing an external limit switch.

The integrated auxiliary switch is rated for multiple control voltages: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, and 0.75 A at 690 V. These are the maximum continuous currents the auxiliary contacts can switch at each voltage level — use the 690 V row when the control circuit is line-fed rather than transformer-isolated. At lower control voltages (24 V, 60 V, 110 V, 125 V, 220 V) the ratings are 2 A, 0.3 A, 0.22 A, 0.22 A, and 0.11 A respectively — the 60 V and 125 V entries cover non-standard control supplies sometimes found in marine or legacy installations.

Motor Power Ratings — Sizing to the Load

At 400 V rated value the relay handles 3 kW; at 500 V it handles 4 kW; at 690 V it handles 5.5 kW. These correspond to the motor full-load current the relay can protect when set correctly. The 480 V and 600 V entries (8 A each) cover North American 60 Hz installations where the relay is applied at those voltages.

Mounting & Integration — What Fits Where

Fastening method is contactor mounting — the relay clips directly onto the matching SIRIUS contactor, no DIN rail required. Dimensions: 55 mm wide, 90 mm high, 105 mm deep. Main circuit terminals accept screw-type connections: 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid or stranded. Use a Pozidriv PZ2 screwdriver with 5–6 mm shaft diameter.

Temperature compensation is active from -40 to +60 °C, meaning the relay's trip characteristic stays accurate across that span without manual adjustment. Substance prohibitance date of 09/08/2017 aligns with RoHS and REACH compliance documentation available from Siemens for this part.

Frequently asked questions

What is the 'Tripped' message note on 3RU2136-1HB0?

The note 'for message Tripped' refers to the integrated auxiliary switch contact that changes state when the overload relay has tripped, providing a direct fault signal to a PLC or indicator.

What are the key ratings of 3RU2136-1HB0?

Trip Class 10, rated voltage 690 V, Size S2. Motor power ratings: 3 kW at 400 V, 4 kW at 500 V, 5.5 kW at 690 V. Auxiliary contact: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V, 0.75 A at 690 V.

Where can I buy 3RU2136-1HB0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for 3RU2136-1HB0?

The part carries a substance prohibitance date of 09/08/2017, consistent with RoHS and REACH compliance. Standard Siemens documentation includes the CE declaration and, where applicable, UL/CSA certification for the SIRIUS family.

MPN
3RU2136-1HB0