Skip to main content
Siemens 3RU2136-4DB0-ZX95 — Overload Relays

Siemens 3RU2136-4DB0-ZX95 SIRIUS thermal overload relay, 25

MPN3RU2136-4DB0-ZX95

Siemens SIRIUS thermal overload relay, size S2, 25 A rated operational current, Trip Class 10, contactor mounting, screw terminals, 3RU2136-4DB0-ZX95.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2136-4DB0-ZX95 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
3RU2136-4DB0-ZX95 — Protection & Trip
ParameterValue
Overload current setting range18 ... 25 A
Trip classCLASS 10
Overload release typethermal
3RU2136-4DB0-ZX95 — Electrical (main circuit)
ParameterValue
Rated operational current25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)10.5 W
Per pole3.5 W
3RU2136-4DB0-ZX95 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2136-4DB0-ZX95 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 2), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2136-4DB0-ZX95 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2136-4DB0-ZX95 — Mechanical
ParameterValue
Width55 mm
Height90 mm
Depth105 mm

Product details

The Siemens SIRIUS 3RU2136-4DB0-ZX95 is a thermal overload relay sized S2, rated 25 A operational current, with Trip Class 10.

Rated operational current is 25 A at both 480 V and 600 V, so it handles the same load regardless of whether your motor is on a 480 V or 600 V distribution. The operating voltage rating of 690 V covers the main circuit voltage for most industrial motor feeders. The auxiliary contact ratings are given per voltage: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, 1 A at 400 V — these are the switching capacities for the trip-indication contact, so confirm your control voltage matches one of these curves. The relay is temperature-compensated from -40 °C to +60 °C, meaning the trip point stays accurate across the typical panel ambient range.

Fastening method is contactor mounting — it clips directly onto the matching SIRIUS contactor, no DIN rail required for the relay itself. Main circuit terminals are screw-type, accepting 2× (0.5…1.5 mm²) or 2× (0.75…2.5 mm²) solid or stranded copper, or AWG 18…2 for two conductors. The auxiliary/control circuit also uses screw terminals. Screwdriver shaft diameter 5…6 mm, Pozidriv PZ 2 tip. Mounting position is any, which helps in tight enclosures. Dimensions: 55 mm wide, 90 mm high, 105 mm deep.

Frequently asked questions

Where can I buy 3RU2136-4DB0-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the Trip Class and what does it mean?

Trip Class 10 means the relay will trip within 10 seconds at 7.2× the current setting — standard for protecting motors that start under normal load without prolonged inrush.

What does the note 'for message Tripped' refer to?

The built-in auxiliary switch includes a contact labeled for the 'Tripped' message — it closes when the relay has operated, giving a remote signal to a PLC or annunciator.

Will 3RU2136-4DB0-ZX95 drop into a panel designed for 3RU2116-1FC1?

Both are SIRIUS S2 size overload relays with the same contactor-mounting footprint, so the mechanical fit is the same. The difference is the current range: 3RU2136-4DB0-ZX95 is rated 25 A, while 3RU2116-1FC1 covers a lower range. Check your motor FLA before swapping.

MPN
3RU2136-4DB0-ZX95