Skip to main content
Siemens 3RU2136-4FD1 — Overload Relays

Siemens 3RU2136-4FD1 SIRIUS Thermal Overload Relay, Size S2,

MPN3RU2136-4FD1
Active

Siemens SIRIUS thermal overload relay, Size S2, Trip Class 10, 690 V rated, 50-60 Hz, screw terminals, integrated auxiliary switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RU2136-4FD1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RU2136-4FD1 — Protection & Trip
ParameterValue
Overload current setting range28 ... 40 A
Trip classCLASS 10
Overload release typethermal
3RU2136-4FD1 — Electrical (main circuit)
ParameterValue
Rated operational current40 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)15.6 W
Per pole5.2 W
3RU2136-4FD1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2136-4FD1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 2), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)
3RU2136-4FD1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2136-4FD1 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth117 mm

Product details

It uses a thermal bimetallic release and is rated for a main circuit voltage up to 690 V at 50-60 Hz. The relay includes an integrated auxiliary switch that provides a separate signal contact for the control circuit, so a PLC or HMI can read the tripped state directly. The auxiliary contacts are rated for switching at various control voltages: 2 A at 24 V, 3 A at 120 V, 2 A at 230 V, and 1 A at 400 V. This covers common control voltages in industrial panels without needing an extra interface relay. The screw terminals on the main current circuit accept 2×(0.5–2.5 mm²) solid or stranded wire — a Pozidriv PZ2 screwdriver tip is what you want on the van. Stand-alone installation means it doesn't need a separate base or adapter; it mounts directly to the contactor or panel.

Compliance documentation is available: the evidence notes a substance prohibitance date of 10/15/2014, aligning with RoHS and REACH requirements. The relay carries the SIRIUS brand, and standard Siemens documentation includes a CE declaration and UL/CSA file numbers — request these with your RFQ if your quality system needs them on file.

Dimensions and fit

The relay measures 55 mm wide, 105 mm tall, and 117 mm deep. The width (55 mm) matches the S2 contactor footprint, so it aligns directly with the 3RT2 series contactors without needing a separate adapter.

Frequently asked questions

What is 3RU2136-4FD1's listed note (for message 'Tripped')?

The relay carries a note indicating it is designed for message 'Tripped', meaning the integrated auxiliary switch provides a signal that can be wired to a PLC or indicator to show the relay has tripped due to overload or phase loss.

What is 3RU2136-4FD1's listed depth?

The depth is 117 mm. That's the dimension from the mounting surface to the furthest projection — important for enclosure depth planning.

Will 3RU2136-4FD1 drop into a panel specified around 3RU2116-1FC1?

Both are SIRIUS Size S2 overload relays with the same 55 mm width and 105 mm height. The depth differs: 3RU2136-4FD1 is 117 mm versus 3RU2116-1FC1 at a different depth. Check the depth clearance in your enclosure — if you had room for the 3RU2116-1FC1, the 3RU2136-4FD1 should fit the same contactor footprint, but verify the depth allowance.

Who supplies 3RU2136-4FD1 and how is it quoted for volume purchases?

This part is sourced through independent industrial distribution. For volume or BOM pricing, submit an RFQ — availability and current pricing are confirmed at quote time, not listed here.

What compliance documentation does Siemens provide for 3RU2136-4FD1?

The relay has a substance prohibitance date of 10/15/2014, which aligns with RoHS and REACH requirements. Standard Siemens documentation includes a CE declaration and UL/CSA file numbers — request these with your RFQ.

MPN
3RU2136-4FD1