Skip to main content
Siemens 3RU2136-4GB0 — Overload Relays

Siemens 3RU2136-4GB0 SIRIUS Thermal Overload Relay, Trip Cla

MPN3RU2136-4GB0
Active

Siemens SIRIUS 3RU2136-4GB0 thermal overload relay, size S2, Trip Class 10, rated up to 690 V, with integrated trip message contact.

$55.88Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RU2136-4GB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RU2136-4GB0 — Protection & Trip
ParameterValue
Overload current setting range36 ... 45 A
Trip classCLASS 10
Overload release typethermal
3RU2136-4GB0 — Electrical (main circuit)
ParameterValue
Rated operational current45 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)15.6 W
Per pole5.2 W
3RU2136-4GB0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A
3RU2136-4GB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 2), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
3RU2136-4GB0 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
3RU2136-4GB0 — Mechanical
ParameterValue
Width55 mm
Height90 mm
Depth105 mm

Product details

It is rated Trip Class 10 for standard motor starting, and is rated for up to 690 V. Dimensions: 55 mm wide, 105 mm deep, 90 mm high.

Mounting and Connection

Mounts directly to a contactor via the fastening method (contactor mounting). The main circuit uses screw terminals. It accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire. The auxiliary switch is integrated. Operating temperature range -40 to +70 °C.

Frequently asked questions

What is the note on this component?

It has a note 'for message Tripped', meaning it includes an auxiliary contact for trip indication.

What is the depth of this relay?

The depth is 105 mm.

What compliance documentation does this brand provide?

It has a substance prohibitance (RoHS) compliance date of 10/15/2014.

MPN