Skip to main content
Siemens 3RU2136-4HD1 — Overload Relays

Siemens 3RU2136-4HD1 SIRIUS Thermal Overload Relay, Class 10

MPN3RU2136-4HD1
Active

Siemens SIRIUS 3RU2136-4HD1 thermal overload relay, size S2, Class 10 trip, 22 kW at 400 V AC-3e, screw-type terminals, integrated auxiliary switch.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RU2136-4HD1 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationthermal overload relay
Frame size (overload relay)S2
Combinable contactor sizesS2
Reference code (IEC 81346-2)F

Protection & Trip

3RU2136-4HD1 — Protection & Trip
ParameterValue
Overload current setting range40 ... 50 A
Trip classCLASS 10
Overload release typethermal

Electrical (main circuit)

3RU2136-4HD1 — Electrical (main circuit)
ParameterValue
Rated operational current50 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)15.6 W
Per pole5.2 W

Auxiliary contacts

3RU2136-4HD1 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A, quick: 10 A
Switching current at 24 V2 A
Switching current at 60 V0.3 A
Switching current at 110 V0.22 A
Switching current at 120 V3 A
Switching current at 125 V0.22 A
Switching current at 220 V0.11 A
Switching current at 230 V2 A
Switching current at 400 V1 A

Connection & Mounting

3RU2136-4HD1 — Connection & Mounting
ParameterValue
Mounting / fastening methodstand-alone installation
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalNo
Conductor cross-section: solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 2), 1x (18 ... 1)
Conductor range (AWG), auxiliary contacts2x (20 ... 14)

Environmental

3RU2136-4HD1 — Environmental
ParameterValue
Operating temperature-40 ... +70 °C
Storage temperature-55 ... +80 °C
Transport temperature-55 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m

Mechanical

3RU2136-4HD1 — Mechanical
ParameterValue
Width55 mm
Height105 mm
Depth117 mm

Product details

Class 10 trip and what it means for your motor

The 3RU2136-4HD1 is a SIRIUS thermal overload relay — the bimetallic strip heater that sits between your contactor and the motor, watching for overcurrent. That's fast enough to protect a standard squirrel-cage induction motor during a locked-rotor event without nuisance-tripping on a normal start. The voltage ceiling matches the main contactor's rating, so you can run this on a 690 V distribution system without a separate voltage-reduction tap.

Panel fit and terminal details

Size S2 frame — 55 mm wide, 105 mm tall, 117 mm deep — mounts in any orientation on the DIN rail or directly to the panel backplate (cites:,). The normally-open contact closes when the relay trips, feeding a PLC input or alarm lamp.

Temperature tolerance and compliance

Temperature-compensated from -40 to +60 °C ambient, so the trip curve stays accurate whether the panel is in a hot mill or a cold warehouse (cites:). The substance-prohibitance declaration dates to October 15, 2014 — this relay meets RoHS and REACH requirements for that compliance window (cites:).

Frequently asked questions

Where can I buy the 3RU2136-4HD1 and get a price?

This relay is available through independent industrial distribution. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time, not on the listing.

What does the 'Note for message Tripped' mean on this relay?

That note labels the auxiliary contact function — the integrated switch changes state when the bimetallic strip has tripped, providing a dry-contact signal to a PLC or alarm circuit (cites:,).

MPN
3RU2136-4HD1